INSTALLATION INSTRUCTIONS AND HOMEOWNER’S MANUAL: ELECTRIC FURNACE MODULATING Models: (ECM MOTOR) SUPXX-M240V12 MULTI-POSITION SUPXX-M240V20 INSTALLER / SERVICE TECHNICIAN: Attention: INFORMATION THIS MANUAL Do not tamper with the unit or its controls. INSTALLATION AND SERVICING OF THE FURNACE AND KEEP Call a qualified service technician. THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE.
technician for the installation and subsequent servicing of this furnace; b) Do not use this furnace if any part of it was under water. SAFETY Call a qualified service technician immediately to assess the damage and to replace all critical parts that were in contact with water;...
2.2.2 Supply air ducts Ducts can be installed with a zero clearance to combustible material. 2 INSTALLATION 2.3 CONFIGURATIONS This furnace requires suitable ductwork. This furnace is a true multi-position unit, in that it will function in an upflow, downflow or horizontal configuration to the left or the right.
2.3.3 Horizontal installation The exterior of the unit must have an uninterrupted The return duct may be installed to the back, on the left ground to minimize the risk of bodily harm. A ground side, on the right side or under the unit. The supply duct terminal is supplied with the control box for that purpose.
Figure 5: Communicating thermostat connection in either the supply or return air duct. Carefully follow the instructions provided with these appliances to ensure proper installation and hook-up to the electric furnace. Refrigerant and drainage pipes must in no way hinder access to the furnace panels.
Figure 7: Placement of interface board • CMDMOT: The airflow requested in CFM • ACC: Not used AB STATUS Menu (Auto-backup) This menu displays the operating information associated with the auto-backup function. • ERR DT: The temperature difference between the thermostat temperature and the thermostat setpoint in °F •...
Table 1: Installer Parameters Menu Affects Parameter Description Range Default Note AC/HP TONS Tonnage of outdoor unit 0.75-10 CFM/TON Select CFM/Ton 300-500 DEHUM ON STATE DH signal is active when ON (High) or OFF (Low) HIGH/LOW HIGH DEHUM RATIO Cooling airflow ratio for dehum 50-100% AC Y1 RATIO First stage cooling (Y1) airflow ratio...
a. If indoor temperature is above temperature set point and humidity is above humidity set point, thermostat closes circuits R to G, R to Y/Y2 and 4 OPERATION R to O and humidistat opens circuit R to DH. 4.1 START-UP b.
WARNING 5 MAINTENANCE LECTRICAL SHOCK OR UNIT DAMAGE HAZARD Failure to carefully read and follow this WARNING could result in equipment malfunction, property damage, personal injury and/or death. Disconnect power to unit before removing or WARNING replacing connectors or servicing motor. Wait at least five (5) minutes after disconnecting power LECTRICAL HOCK HAZARD...
REVISIONS REV. DESCRIPTION DATE Figure 9: Furnace Dimensions 559mm 22" 25mm 1" SUPPLY 25mm ALIMENTATION 1" Identical on the 2 sides Identique sur les 2 cotés 559mm 22" 927mm 508mm x 508mm 36 1/2" 20" x 20" Identical on the 2 sides, the back and below.
Page 15
Figure 10: Electrical diagram, S Modulating UPREME...