Panasonic OLED-201806 Technical Manual page 49

Table of Contents

Advertisement

Simple Power On Sequence (FX/FS/FZ Series)
< FX/FS/FZ series >
( Plug in )
STB5V output
TV_SUB_ON signal
16V / 64V(*) /24V(OLED) output / PFC circuit start working
Power On
Power LED Green
Power SW on / Remote on
PANEL_VCC_ON signal
PNL12V output
FX/FS
BL_ON_ON signal
EVDD_ON_ON signal
64V(*) up to VLED
24V output
< Display start >
< Display start >
Also 16V is necessary before Power LED.
Standby
Power Off
Power LED Red
Power LED off
TV_SUB_OFF
TV_SUB_OFF
Stop 16V / 64V(*)
Stop 16V / 64V(*)
FZ
North America :
(Power LED Green RED)
(Power LED Red OFF)
(Power Off no exist)
(*) The DC level is different by the LCD panel.
AC Plug in
STB5V (form P to A)
SUB_ON (from A to P)
16V (from P to A)
Power LED
Panel_Vcc_ON (from A to Panel(TCON))
PNL12V (from A to Panel(T-CON) )
BL_ON/EVDD_ON (from A to P/LDP/PB)
VLED (from P to Panel(Backlight) )
FX/FS
24V (from P/PB to Panel(T-CON))
FZ
5V
Power on
(Standby)
Power on
16V
(Standby)
Standby / Power on
Power on
12V
VLED,
ex. 120V
ex.64V(*)
24V
output to T-CON
49