Start up Operation-7
2
3
< from
to
When the power board receives the TV_SUB_ON signal from IC8000 via pin 9 of
connector P2, it outputs 2 different voltages:
16V to the A board on pins 1, 2, 3 and 4 of connector P2.
64V(*) to the LED drive part.
TV_SUB_ON command is carried to the primary side by PC7302. This voltage is leaded
to Q7202 which provide power supply VCC of PFC circuit. The PFC starts to operate.
Besides this voltage to go to Q7315 whcih provide the mode change signal to pin 3 of
IC7301. The operation of the IC 7301 changes the switching frequency from standby
state to working state because of providing high power current.
Output voltages from transformer T7301 start rising up until the moment when IC7401
started to operate. This IC measures the 16V line output in the secondary side. The
output of this IC is provided by PC7301 to pin 4 of IC7301. IC7301 adjust the switching
frequency by this feedback signal.
The TV_SUB_ON signal also switches on the Q7402/03/04/05 to provide output
voltages (16V and 64V(*) ). The 64V(*) is provided to the LED Backlight Drive. The 16V
is provided to the A board.
.
(*OLED) FZ series : The VCC of PFC also go to IC7501 on PB board and this power IC
also start working. The 24V is provided to the OLED panel power drive.
(*)The DC level is different by the LCD panel.