Low temperature cut-off
This setting is available when a VE.Smart network is set-up and the battery temperature is available
(e.g. by for example using a Smart Battery Sense or a Smart BMV with the optional temperature
sensor). It can be used to disable charging at low temperatures as required by Lithium batteries.
For Lithium Iron Phosphate batteries this setting is preset at 5 degrees Celsius, for the other battery
types it is disabled. When creating a user defined battery the cut-off temperature level can be
adjusted manually.
See the VE.Smart Network manual for details on what devices are capable of transmitting
temperature.
Manual Equalization - Start now
Selecting 'Start now' on 'Manual equalisation' allows manual initiation of an Equalization cycle. To
allow the charger to equalize the battery properly use the manual equalize option only during
absorption and float periods, and when there is sufficient sunlight. Current and voltage limits are
identical to the automatic equalize function. The duration of the equalisation cycle is limited to a
maximum of 1 hour when triggered manually. Manual equalization can be stopped at any time by
selecting 'Stop Equalize'.

4.2 Load output

This section applies to all products. These settings are typically used on the smaller models which
have a dedicated load output (75/10, 75/15, 100/15 and 100/20).
For larger models without a load output, the load settings can be used to drive the TX pin in the
VE.Direct port, which can then be used to drive a BatteryProtect relay or other load-shedding device.
See chapter 4.4 Tx port function, option 5: Virtual Load output, for more information.