13.15 AUTO COMFORT and ECONAVI Operation

AUTO COMFORT start condition:
When AUTO COMFORT button is pressed.
o
AUTO COMFORT stop conditions:
When AUTO COMFORT button is pressed again.
o
When unit is OFF by OFF/ON button.
o
When unit is OFF when OFF TIMER activates.
o
When unit is OFF by AUTO OFF/ON button at indoor unit.
o
When POWERFUL, QUIET operation activates.
o
When ◄► button is pressed.
o
ECONAVI start condition:
When ECONAVI button is pressed.
o
ECONAVI stop conditions:
When ECONAVI button is pressed again.
o
When unit is OFF by OFF/ON button.
o
When unit is OFF when OFF TIMER activates.
o
When unit is OFF by AUTO OFF/ON button at indoor unit.
o
When POWERFUL, QUIET operation activates.
o
When ◄► button is pressed.
o
13.15.1 Human Activity Sensor
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
AUTO COMFORT / ECONAVI initialization
Initialize indication
1
0 – 2 seconds
2
2 – 3 seconds
3
3 – 70 seconds
* □ Indicator ON, ■ Indicator OFF
Human activity judgment is as following
Human Activity Sensor
I
II
III
IV
Repeat Step I to IV