Problem:
E9 appears on the display
unit:
If the above tips do not resolve your problem, call the nearest authorized service centre and state the
type, model, and serial number indicated on the appliance rating plate or label located in the appliance
interior.
38
Cause or remedy:
Door was open for too long. Close the door.
If the door is not open, or if E9 is still displayed 10 minutes after
you have closed the door, then there is a door sensor failure. Call
a service centre to arrange a repair. The appliance will operate
in safe mode until it is repaired. The appliance will automatically
preserve the most suitable temperature for each compartment.