Section 11, Maintenance Schedule - Gardner Denver L4-5C Original User Manual

Frame 0 single stage base-mounted & tank-mounted compressor
Table of Contents

Advertisement

SECTION 11
MAINTENANCE SCHEDULE
SERVICE CHECK LIST
Air Filter and Pre-Filter - Operating conditions determine frequency of service. See "Air Filter," Section 7.
Motor Lubrication, Refer to Section 2.
Every 8 Hours Operation
1.
Check the reservoir oil level, add oil if required. See Section 5..
2.
Observe if the unit loads and unloads properly.
3.
Check discharge pressure and temperature.
4.
Check control panel display for advisory text messages.
Every 125 Hours Operation
1.
Check for dirt accumulation on oil, air core finned faces and the cooling fan. If cleaning is required,
clean the exterior fin surfaces of the cores by blowing compressed air carrying a nonflammable
safety solvent in a direction opposite that of the cooling fan air flow. This cleaning operation will
keep the exterior cooling surfaces clean and ensure effective heat dissipation.
Every 2000 Hours Operation
1.
Change oil filter element.
Every 4000 Hours Operation
Change the compressor lubricant. Under adverse conditions, change more frequently (refer to "Oil
1.
Change Interval", Figure 5-2. Flush system if required.
Every Year
1.
Check the pressure relief valve for proper operation. See Section
Change oil separator. See "Removal of Oil Separator for Inspection or Replacement", Section 5, for
2.
further details.
13-25-629 v03