STARTING THE UNIT - Observe the following starting procedures:
Unit Cold or Hot:
1. When using a Total System with a compressed air dryer option, refer to Section 10 for operating
details.
2. Open the air service valve (customer furnished) between the main air system and the check valve
on the package.
3. Turn on power to the compressor package. Press the (Ө) key to clear faults (if present), then
press the ( I ) key to start the unit.
4. Run for approximately several minutes until the temperature stabilizes.
5. The unit is equipped with a minimum 70 psig pressure/check valve. No special procedure is
required to maintain the unit reservoir pressure.
DAILY CHECK - Refer to "Maintenance Schedule", Section 11.
STOPPING THE UNIT:
1.
To stop compressor operation, press the (O) key.
2.
Wait approximately one minute to allow the compressor to stop. The oil reservoir will automatically
blow down as the motor stops.
3.
When using a Total System with a compressed air dryer option, refer to Section 10 for operating
details.
13-25-629 v03
Page 21