Symmons Sereno ActivSense S6430E Sereno ActivSense S6430BSTS Installation And Maintenance Manual

Symmons Sereno ActivSense S6430E Sereno ActivSense S6430BSTS Installation And Maintenance Manual

Sensor faucet

Advertisement

Quick Links

S6430B/E SENSOR FAUCET
E L E C T R O N I C L A V A T O R Y F A U C E T
I NS
I NST T ALLA
ALLAT ION
T ION AND
AND MAINT ENA NC
MAINT ENA NCE E GU IDE
GU IDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sereno ActivSense S6430E Sereno ActivSense S6430BSTS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Symmons Sereno ActivSense S6430E Sereno ActivSense S6430BSTS

  • Page 1 S6430B/E SENSOR FAUCET E L E C T R O N I C L A V A T O R Y F A U C E T I NS I NST T ALLA ALLAT ION T ION AND AND MAINT ENA NC MAINT ENA NCE E GU IDE GU IDE...
  • Page 2: Technical Data

    INDEX TEchNIcal DaTa TECHNICAL DATA PACK CONTENTS PRE-INSTALLATION INFO INSTALLATION BATTERY REPLACEMENT SETTINGS ADJUSTMENT SPARE PARTS LIST MAINTENANCE LIMITED WARRANTY S6430B S6430E BATTERY POWERED ELECTRIC POWERED TROUBLESHOOTING Power supply 6X1.5V AA batteries or 9V transformer 0.5-8.0 7-116 bar ( PSI) Recommended water With water pressure of more than 8 bars, use a pressure reduc- pressure...
  • Page 3: Pre-Installation Info

    Pack coNTENTs PrE-INsTallaTIoN INFo CHeCk ContentS Familiarize yourself with the part names and confirm that the parts are included. Separate all parts from the packaging and check each part with the “Pack contents” section. Pay attention to the different models variations. Make sure all parts are accounted for before discarding any packaging material.
  • Page 4: Installation

    INsTallaTIoN INsTallaTIoN sTEP 3 – coNNEcTINg ThE waTEr suPPly sTEP 1 – PrEParaTIoN For MouNTINg ThE FaucET Connect the flexible pipe to the water Shut off the water supply. supply. For models with temperature control connect the red flexible pipe to the hot water supply and the blue flexible pipe to the cold water supply.
  • Page 5 INsTallaTIoN BaTTEry rEPlacEMET When the battery weakens, the LED indicator light will blink at a constant rate. The battery sTEP 4 – coNNEcTINg ThE PowEr sourcE must be replaced within two weeks. BatteRY VeRSion Install the batteries in the battery box and attach the box to the wall underneath the sink.
  • Page 6: Settings Adjustment

    sETTINgs aDjusTMENT sETTINgs aDjusTMENT DELAY IN TIME: If required, the delay in time can also be modified as DETECTION follows: Press the IN button. Wait until a quick flashing of the LED in the DELAY OUT TIME RANGE sensor eye is perceived. Then, press + to increase the delay in time and – to reduce it.
  • Page 7: Spare Parts List

    lIMITED warraNTy sParE ParTs lIsT SEALS AND SCREWS KIT SF250 The manufacturer warrants that its electronic products will be free of defects in material and workmanship during normal use for two years from the date the product is 10-PACK SENSOR KIT SF252 purchased.
  • Page 8: Troubleshooting

    TrouBlEshooTINg ProBlEM INDIcaTor causE soluTIoN No water 1. Sensor flashes coming out continuously of the faucet: when user’s Low battery. Replace battery hands are within the sensor’s range. 2. LED in the 1. Range is too short. Increase the range sensor does not 2.
  • Page 9 Braintree, MA 02184-3804 1-800-796-6667 01500501-A 10.2020 Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621 Copyright © 2020 Symmons Industries, Inc. ■ symmons.com ■ gethelp@symmons.com ■ ZV-3422 REV A ■ 101320...

This manual is also suitable for:

Sereno activsense s6430b

Table of Contents