Accessories And Compliance; Accessories List - Carrier CRECOMZR076A00 Installation Instructions Manual

Small rooftop products select 3 to 15 tons
Table of Contents

Advertisement

Table 3 — ICP Usage Chart
ICP MODEL NUMBER
Small Cabinet
RGV/RAV/RHV 036-072
RGW/RAW/RHW 036-060
RGH/RAH/RHH 036-060
RGS/RAS/RHS 072
RGX/RAX/RHX 036-060
Large Cabinet
RGV/RAV 090-150
RHV 090-120
RGW/RAW 072-120
RHW 072-102
RGH/RAH 072-120
RHH 072-102
RAS/RGS 090-150
RHS 090-120
Extra Large Cabinet
RGV/RAV 180
RHV 180
RGW/RAW 150
RHW 120
RGH/RAH 150
RHH 120
RAS/RGS 180
RHS 150
Table 4 — Package Contents
ECONOMIZER
QTY
PART NUMBER
EconoMi$er Damper Assembly with
1
Actuator and HH79AH001 (HW: C7250)
Outside Air Sensor
HW63AW002 (HW: W7220) Controller
1
with Attached Harness†
1
HH79ZZ007 Mixed Air Temp Sensor*
CRECOMZR076A00,
CRECOMZR078A00
1
48TMHSRSE--A20 4-Wire Harness†
1
Hood Assembly with Top and 2 Sides
1
Hood Divider
1
Aluminum Filter
1
Hardware Bag*
EconoMi$er Damper Assembly with
1
Actuator and HH79AH001 (HW: C7250)
Outside Air Sensor
HW63AW002 (HW: W7220) Controller
1
with Attached Harness†
1
HH79ZZ007 Mixed Air Temp Sensor*
CRECOMZR080A00
1
48TMHSRSE--A20 4-Wire Harness†
1
Hood Assembly with Top and 2 Sides
1
Hood Divider
1
Hood Filter Divider
2
Aluminum Filter
1
Hardware Bag*
* Shipped in hardware kit for field installation.
†Wiring Harness is shipped with original unit, not with kit.
HW = Honeywell
ECONOMI$ER
X
®
PART NUMBER
CRECOMZR076A00
CRECOMZR078A00
CRECOMZR080A00
CONTENTS
Table 5 — EconoMi$er X Sensor Usage
ECONOMI$ER X WITH OUTDOOR AIR
APPLICATION
Outdoor Air
The HH79ZZ007 outdoor air dry bulb sensor is
Dry Bulb
Mixed Air
HH79ZZ007 provided with economizer and field
Sensor
Single
Enthalpy
Differential
CRDIFRASN01A00†† (When available, or
Dry Bulb or
MicroMetl part number 9901-2022-DIFF JC2)
Enthalpy
CO
for DCV
2
Control using
a Wall-Mounted
CO
Sensor
2
33ZCSENCO2 or
CO
for DCV
2
CGCDXSEN004A00*
Control using
a Duct-Mounted
33ZCSENCO2 or
CO
Sensor
2
CGCDXASP00100†
* Accessory CO
sensors.
2
†Accessory aspirator boxes required for duct-mounted applications.
** CRCBDIOX005A00 is an accessory that contains both 33ZCSENCO2
and 33ZCASPCO2 accessories.
†† Includes HH57AC081 sensor and wiring harness.

ACCESSORIES AND COMPLIANCE

Accessories List

The EconoMi$er X system has several field-installed accessories
available to optimize performance. Refer to Table 6 for authorized
parts and power exhaust descriptions.
Table 6 — EconoMi$er X Field-Installed Accessories
DESCRIPTION
208/230v 1PH Power Exhaust for Small
Cabinet
460v 3PH Power Exhaust for Small
Cabinet
208/230v 1PH Power Exhaust for Large
Cabinet
460v 3PH Power Exhaust for Large
Cabinet
208/230v 1PH Power Exhaust for Extra
Large Cabinet
460v 3PH Power Exhaust for Extra
Large Cabinet
Enthalpy Sensor (OA)
Differential (Return) Sensor
CO
Sensor and Aspirator Box
2
Return Air CO
Sensor (4 to 20 mA)
2
CO
Room Sensor (4 to 20 mA)
2
Aspirator Box for Duct Mount CO
Sensor (4 to 20 mA)
Economizer Angle Seal Kit for use with
unit's with Hinged Filter Door - for
Small Cabinet
Economizer Angle Seal Kit for use with
unit's with Hinged Filter Door - for
Large Cabinet
Economizer Angle Seal Kit for use with
unit's with Hinged Filter Door - for Extra
Large Cabinet
* When available, or order MicroMetl PN 9901-2022-DIFF JC2.
3
DRY BULB SENSOR
ACCESSORIES REQUIRED
factory installed on economizer.
installed in blower compartment.
HH57AC081
33ZCSENCO2
or
CGCDXSEN004A00
and
or
CRCBDIOX005A00**
PART NUMBER
CRPWREXH030A01
CRPWREXH021A01
CRPWREXH022A01
CRPWREXH023A01
CRPWREXH080A00
CRPWREXH081A01
HH57AC081
CRDIFRASN01A00*
CRCBDIOX005A00
CRCBDIOX002A00
33ZCSENCO2 or
CGCDXSEN004A00
33ZCASPCO2 or
2
CGCDXASP001A00
CRPECONV003A00
CRPECONV004A00
CRPECONV007B00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crecomzr078a00Crecomzr080a00

Table of Contents