Mitsubishi FR-E520-0.1K-NA Instruction Manual page 162

Transistorized inverter, high performance & high function
Table of Contents

Advertisement

( 3 ) Set the required value in Pr. 160 to make the user group or groups
valid or invalid.
Pr. 160 Setting
0
1
10
11
Note: 1. The Pr. 77, Pr. 160 and Pr. 991 values may always be read independently of
the user group setting.
2. The Pr. 173 or Pr. 174 value read indicates the number of parameters
registered to group 1, and the Pr. 175 or Pr. 176 value read indicates the
number of parameters registered to group 2.
3. If "0" is set in the second digit of two-digit Pr. 160, it is not displayed.
However, "0" is displayed when it is set in the first digit only.
4. When "9999" is set in Pr. 174 or Pr. 176, the parameters registered to the
corresponding user group are batch-deleted.
Description
Previous parameters read
User group 1's parameters read
User group 2's parameters read
User group 1 and 2 parameters read
147
PARAMETERS

Advertisement

Table of Contents
loading