6
Inspection and maintenance
Testing
Type of test
Visual inspection
Mechanical inspection
Safety check (exit and escape routes)
Function testing
Test run
Servicing
Type of servicing
Adjustment and cleaning
For documentation and information purposes, the testing and servicing work as well as the condition
of the system are recorded in a test log book. The test log book must be kept for at least one year or
until the next testing/servicing.
6.2

Operator duties

Personal protection requires compliance with the standards and guidelines for publicly accessible fa-
cilities.
The system operator is responsible for carrying out testing and servicing.
NOTICE
According to EN 16005 / DIN 18650, the system must be inspected by an expert before initial
commissioning and subsequently according to the manufacturer's instructions or at least
once a year
NOTICE
The installation must be inspected during the function and safety check for imbalance and
signs of wear or damage to cables, springs and fastening parts.
The equipment must NOT be used if repair or adjustment work needs to be carried out.
26 / 32
Action
Check door leaves, guides, bearings, limiting devices,
sensors, and the securing of crushing and shearing
points for damage.
Check fastenings for tight fit.
Check sensors, safety devices, and monitoring devices
for tight fit and damage.
Check functioning of switches, operators, controllers,
power or energy storage devices, and sensors.
Also check the adjustment of the safety devices and the
setting of all movement sequences including the end
points.
Final overall review is carried out.
Action
Clean and adjust bearings, sliding points, and power
transmission.
Check relevant fastening screws and retighten if neces-
sary.