Record FlipFlow TWIN User Manual
Hide thumbs Also See for FlipFlow TWIN:

Advertisement

Quick Links

User Manual
FlipFlow TWIN
© Copyright agtatec ag 2019
Manufacturer
Distributor
record-USA
record-USA
4324 Phil Hargett Court
4324 Phil Hargett Court
Monroe, NC 28110, USA
Monroe, NC 28110, USA
BAL_FF_TWIN_EN-USA_2V1_REC_121-006454534

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlipFlow TWIN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Record FlipFlow TWIN

  • Page 1 User Manual FlipFlow TWIN © Copyright agtatec ag 2019 Manufacturer Distributor record-USA record-USA 4324 Phil Hargett Court 4324 Phil Hargett Court Monroe, NC 28110, USA Monroe, NC 28110, USA BAL_FF_TWIN_EN-USA_2V1_REC_121-006454534...
  • Page 2: Table Of Contents

    General safety and accident prevention regulations..............Presentation of warning signs ......................Intervention rules on sites ......................Preparation advice ..................... Necessary training .......................... FlipFlow Twin description ................... General presentation ........................Control panel position ........................FlipFlow traffic lights ........................3.3.1 Entrance door signals ........................
  • Page 3 Table of contents Conduct during power failure (battery pack optional) .......... Possible errors / alarms ..................Wrong direction alarm ........................Technical alarms ..........................Intrusion alarm ..........................Anti-pass-back alarm........................BMS information ....................Instructions sent from the BMS ...................... Information received by the BMS ....................BAL_FF_TWIN_EN-USA_2V1_REC_121-006454534 3/ 31...
  • Page 4: Regulations

     Test the safety devices of the door at least once a day (see chapter „FlipFlow daily safety check“  Keep the installation properly operating and balanced  Call a record technician for service or have trained door systems technician make repairs to the installation  Save these instructions...
  • Page 5 Regulations IMPORTANT When using motion detectors, make sure that no moving objects such as flags, plants, etc. enter the detection areas of the motion detectors IMPORTANT In order to avoid malfunctions, the system must be disconnected from the mains overnight! IMPORTANT If malfunctions that endanger the safety of individuals occur, the system must be turned off.
  • Page 6: Presentation Of Warning Signs

    Regulations Presentation of warning signs Various symbols are used in this guide for easier understanding: NOTICE Useful advice and information to ensure correct and efficient workflow of the system. IMPORTANT Specific details which are essential for trouble-free operation of the system. IMPORTANT Important details which must be read for proper function of the system.
  • Page 7 Regulations IMPORTANT Before starting work on the door, ensure that all equipment and tools are in good working order and conform to current safety standards. IMPORTANT Do not change the components of the automation system in any way. NOTICE Labeling and information must be visible to everyone. NOTICE Ensure regularly that all safety systems are in good working order.
  • Page 8: Preparation Advice

    Preparation advice Preparation advice Necessary training The record training center fulfils all relevant training requirements you will be faced with (consultancy, inter-company training, customized training etc.) and puts its skills at your disposal by providing you with its training catalogue.
  • Page 9: Flipflow Twin Description

    FlipFlow Twin description FlipFlow Twin description General presentation 1 – Entrance door 2 – Exit door 3 – Hand rail (Option) 4 – Protective screen (Option) BAL_FF_TWIN_EN-USA_2V1_REC_121-006454534 9/ 31...
  • Page 10: Control Panel Position

    FlipFlow Twin description Control panel position The control panel BDE-S (for the selecting the operating mode) is located in the on the cladding be- hind the cover of the entrance door. The control panel BDE-S for the FlipFlow This control panel is used to switch between the various operating modes of the FlipFlow.
  • Page 11: Entrance Door Signals

    FlipFlow Twin description 3.3.1 Entrance door signals 3.3.2 Exit door signals BAL_FF_TWIN_EN-USA_2V1_REC_121-006454534 11/ 31...
  • Page 12: Description Of Use

    Description of use Description of use How to operate the BDE-S control panel The BDE-S is a 5 position, key operated control panel; simply insert the key and then turn until the desired selection corresponds with the indicator lit. Each rotation of the key changes which LED is lit. The BDE-S has a standard European half- cylinder.
  • Page 13: Operating Modes And Functions

    Operating modes and functions Operating modes and functions CLOSED and LOCKED operating mode Also serves as a manual reset Status of the FlipFlow: ▪ Illumination is off. ▪ LED-Strips and pictograms are red. ▪ Doors are closed and locked. NOTICE Configurable: •...
  • Page 14: Flow Operating Mode

    Operating modes and functions NOTICE Configurable: • Activation / deactivation of the sensors and movement detection. IMPORTANT In this mode, the security level is compromised! If detection in the tunnel is deactivated, it is possible to pass through in both directions without trigger- ing an alarm.
  • Page 15 Operating modes and functions Cycle: ▪ A passenger arrives in front of the entrance radar, the door opens. ▪ A passenger enters the tunnel, the door clos- es again (if another passenger arrives, the door stays open). ▪ A passenger arrives in front of the exit door, and the door opens.
  • Page 16: Interlock Operating Mode

    Operating modes and functions INTERLOCK operating mode INTERLOCK mode has fewer passage varieties than FLOW mode but offers maximum security, even between two arrivals, a time where the number of passengers is low. Initial state: ▪ Illumination is on. ▪ Entrance door is closed. ▪...
  • Page 17 Operating modes and functions ▪ The exit door opens as soon as the entrance door is closed. Simultaneously, the exit door LED-Strips switches to green and the en- trance door LED-Strips flashes. ▪ The tunnel empties, the exit door closes again.
  • Page 18: Interlock Operating Mode / Auto-Flow

    Operating modes and functions INTERLOCK operating mode / AUTO-FLOW The automatic selection allows one to combine the advantages of both operating modes in relation to safety and the best passenger comfort. During low traffic periods (which present the highest risks), the FlipFlow switches to INTERLOCK mode to ensure a maximum level of security.
  • Page 19 Operating modes and functions ▪ If the number of passengers exceeds the pre- set threshold value the FlipFlow changes to FLOW mode and operates as described above. ▪ The flow level is higher than the fixed thresh- old value the FlipFlow remains in FLOW mode and operates as previously described.
  • Page 20: Powersave Function

    Operating modes and functions POWERSAVE function If the FlipFlow is not used for a certain time, the lights turn off and switch back on automatically for the next cycle. NOTICE Configurable: • Activation / deactivation of functions. • Setting the idle time delay. CLEANING mode This mode allows the FlipFlow to be cleaned without triggering an alarm while keeping the entrance door closed and locked.
  • Page 21: Test Mode - Without Alarm Function

    Operating modes and functions TEST mode – without alarm function This function allows the FlipFlow operating modes to be tested without triggering an alarm (no alarm signal transmitted to the BMS). This function can be activated by turning the rotary button on the con- trol panel.
  • Page 22: Authorized Access Airside

    Operating modes and functions Maintenance public area (landside): ▪ Entrance door is closed and locked. ▪ Exit door is open. NOTICE Configurable: • Opening side (land / air) • Blink delay 5.10 Authorized access airside When this function is activated, an authorized person is entitled to pass through the FlipFlow in the opposite direction.
  • Page 23: Emergency Opening

    Operating modes and functions 5.11 Emergency opening When this function is activated, the FlipFlow doors open regardless of the status of the safety sen- sors. This mode is activated in case of fire or emergency by a remote switch in the building management system.
  • Page 24: Flipflow Daily Safety Check

    FlipFlow daily safety check FlipFlow daily safety check IMPORTANT Please perform once per day the following safety check Daily safety check 1. Set the FlipFlow to "FLOW" mode. 2. Approach the entry door and remain in the safety beam zone of the open door for 10 seconds.
  • Page 25: Conduct During Power Failure (Battery Pack Optional)

    Conduct during power failure (battery pack optional) Conduct during power failure (battery pack optional) In the case of a power failure, the entrance door closes and locks, the exit door unlocks and opens. The FlipFlow remains in this position until the main power supply returns. This function is only possi- ble with an optional battery pack.
  • Page 26: Possible Errors / Alarms

    Possible errors / alarms Possible errors / alarms Wrong direction alarm Below a list of situations which can set off a wrong direction alarm (=buzzer). Adjustable timers are implemented to manage the offset of these alarms. Category groups „Alarm Disturbance Flow of per- sons“...
  • Page 27 Possible errors / alarms NOTICE Configurable: • Setting all timers relevant to triggering the alarms A person or object remains under the entrance door or in zone 2a, the entrance door opens. A person or object remains under the exit door or in zone 3, the exit door opens. The entrance and exit doors are no longer in their end positions.
  • Page 28 Possible errors / alarms NOTICE Configurable: • Setting all timers relevant to triggering the alarms With this option, entrance door closed, a presence is detected on the floor. NOTICE Configurable: • Activation/deactivation of floor detection in FLOW mode With this option, entrance door closed, a presence is detected on the wall or ceiling. With this option, activating of the emergency open button generates a technical alarm.
  • Page 29: Technical Alarms

    Possible errors / alarms NOTICE Configurable: • Setting all timers relevant to triggering the alarms Example of the anti-pass-back system operation A person crosses the exit door threshold in the opposite direction, an alarm is triggered and the entrance door closes (TOF-Sensor). Technical alarms This alarm is triggered if a traffic flow interruption has lasted too long or if a technical error has been detected.
  • Page 30: Anti-Pass-Back Alarm

    Possible errors / alarms Anti-pass-back alarm This alarm is triggered when the wrong direction is detected or if the entrance door does not close within a reasonable time (see below). A reset is required to deactivate this alarm. NOTICE Configurable: •...
  • Page 31: Bms Information

    BMS information BMS information It is possible to receive and transmit information to the FlipFlow BMS (Building Management System) via dry contact relays. A rotary dial for selecting the operating mode in each vestibule installed is also provided for controlling the FlipFlow from a distance. Instructions sent from the BMS An emergency opening command, with absolute priority.

Table of Contents