120-240 volt / 8000 watt a-c deluxe portable generator

Advertisement

OPERATION
KNOW YOUR GENERATOR
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR GENERATOR,
Compare the
illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments,
Save this
manual for future reference
AC CIRCUIT BREAKERS
ENGINE
RUN/STOP
SWITCH
IDLE CONTROL SWITCH
12VOLT,
t0AMP
BATTERY CHARGE
RECEPTACLE
120VOLTS"DUPLEX"
RECEPTACLES
120VOLTS,
20
RECEPTACLE
120VOLTS,
30AMi
RECEPTACLE
12(_240VOLTS,
30AMP
RECEPTACLE
240VOLTS,
50 AMP
RECEPTACLE
CLEANER
V-TWIN ENGINE
RLTER
ENGINE RUN/STOP SWITCH -- Must be set to RUN to
start the engine
Set switch to STOP to stop the engine
120 VOLTS "DUPLEX" RECEPTACLES
-- May be used
to suppIy electrical power for the operation of 120 voits at
20 amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads
120 VOLTS, 30 AMP RECEPTACLE --
May be used to
supply electrical power for the operation of 120 volts at 30
amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tooi and motor ioads Twistlock connectors are
required when using this receptacle
120 VOLTS, 20 AMP RECEPTACLE
-- May be used to
supply electrical power for the operation of 120 volts at 20
amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads
Twistlock connectors are
required when using this receptacle
120/240 VOLTS RECEPTACLE --
May be used to supply
electrical power for the operation of up to 240 volts at 30
amps AC, single phase, 60 Hz, AC electrical
lighting,
appliance, tool and motor loads Twist]ock connectors are
required when using this receptacle
AC CIRCUIT
BREAKERS
--
Protects
the generator
against electrical ovedoad
Breakers are "push to reset"
type for 15-amp, 20-amp and 30-amp loads.
SPARK ARRESTOR MUFFLER -- Exhaust muffter has a
spark arrestor screen
240 VOLTS, 50 AMP RECEPTACLE
-- May be used to
supply electrical power for the operation of up to 240 volts
at 50 amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads
Range connectors
are
required when using this receptacle
FUEL LEVEL GAUGE - Indicates level of fuel in fuel tank

Advertisement