Config Menu ⇒ Printer

LAN Emulation (LAN Interface only)

Twinax Emul (Twinax/Coax only)

Dump Mode

I/O Hold Time

Operator Manual
3–60
Parameter
HP 2564C
Character Set Roman-8
OCR-A
ANSI
OCR-B
ANSI
Auto CR
OFF
Line Wrap
OFF
Wrap LF
OFF
Code 7F
Fill
VT Channel
12
Skip When
After
This parameter is used to select the emulation attached to the Ethernet port when
using the LANPlex interface. The options are the same as for the Ser/Par Emula-
tion.
This parameter is used to select the Twinax emulation when using the FourPlex
interface. The options are IBM 4234, IBM 4210, and IBM 5225. The default is
IBM 4234. The Coax emulation will always be IBM 4234.
This parameter is used to troubleshoot problems that may arise when processing
data. It places the printer into a Hex Dump Mode. You can select three styles of
printouts for use as debugging tools. The selections are:
OFF:
Dump Mode is disabled. (Default selection)
Style1: Two column output. Text, spaces, and control codes are printed in
hexadecimal code format in one column and ASCII equivalents in
another column.
Style2: Only control codes are printed in hexadecimal format. ASCII characters
are printed as is and escape sequences force a new line.
Style3: Control codes and spaces are printed in hexadecimal format. ASCII
characters are printed as is and escape sequences force a new line.
Twinax Interface
There is only one style for Twinax. It is similar to the Serial/Parallel Style 1,
except the Hex codes are EBCDIC instead of ACSII.
Coax Interface
There is only one style for Coax. It is a unique dump mode that prints the
contents of the PCIA buffer associated with each data buffer.
IPDS Option
If the IPDS option is installed, the dump from the IPDS data stream will be
uniquely formatted regardless of the Dump Mode selection.
This parameter allows you to set the amount of time the printer remains locked
onto the I/O on which it is receiving data after data transmission stops. You can
set this to be 5 - 600 seconds. Default is 30 seconds.
DEC LG01
Epson FX-1180
DEC
Italic
ANSI
ANSI
DIN
ANSI
OFF
ON
OFF
ON
OFF
ON
FILL
Delete Char
12
N/A
After
N/A
IBM Proprinter
MTPL
Code Pg 437
Code Pg 437
ANSI
ANSI
ANSI
ANSI
ON
ON
ON
ON
ON
ON
Ignore
Delete Buffer
N/A
N/A
N/A
N/A