No Form Feed or Extra Page Comes Out

No Form Feed or Extra Page Comes Out
Unix text jobs may also have problems outputting the last page of a
job especially when the BSD Remote (LPD) print method is used.
This means the form feed button has to be pressed on the printer to
get this last page out.
To make this process automatic, tell the PrintNet to handle this task
by setting this feature "on" in the appropriate model. The command
syntax is:
set model modelname trailer $FF
save
For example, if printing to the destination, d2prn, the associated
model is m2. Therefore, the command is:
set model m2 trailer $FF
save
For default destination model mappings of the PrintNet, please see
"PrintNet Naming Schemes" on page 173.
Front Panel Message – Dynamically Set Params
Read Only
This is not an error. It is an informational message warning that the
IP address has been dynamically set by either dhcp, rarp, or bootp.
To assign a static IP address, turn off the rarp, bootp, and dhcp on
the PrintNet. Use the following procedure:
1. Telnet to the PrintNet. Login = root, password = (Enter key)
Telnet commands are:
store tcpip 1 opts -bootp -dhcp
store tcpip tcp opts -zeroIPArp
reset
Wait two minutes for the PrintNet to reset.
2. Program the IP address, Subnet Mask and Gateway (if
required) from the front panel.