Electrical Connection - Miele CS1028 G Installation Instructions Manual

Table of Contents

Advertisement

This appliance must be grounded
according to local or national codes.
All electrical work should be
performed by a qualified electrician
in accordance with local codes and
with the:
-
National Electrical Code
ANSI / NFPA No. 70
for the USA
or
-
Canadian Electrical Code Part I
for Canada
(CSA Standard C 22.1).
,
WARNING
Disconnect the appliance from the
main power supply before
installation or service. To reduce the
risk of electric shock, make sure that
the appliance is properly grounded
after installation.
Power supply
The automatic ignition requires that the
combiset be connected to a 120 VAC,
60 Hz power supply. The supply line
should be protected by a 15 A fuse.
Actual power consumption (during
ignition only) is 25 W.
This appliance is equipped with a
78 3/4" (2000 mm) long power cord that
is ready for connection to the
appropriate outlet.
Place the power outlet so that it is
accessible after the appliance has
been installed in the countertop.

Electrical connection

This appliance is equipped with a
three-prong grounding plug to
prevent shock hazards. It should be
plugged directly into a properly
grounded outlet. Do not cut or
remove the grounding prong from
the plug. If the plug does not fit the
outlet, have the proper outlet
installed by a licensed electrician.
To guarantee the electrical safety of
this appliance, continuity must exist
between the appliance and an
effective grounding system. It is
imperative that this basic safety
requirement be met. If there is any
doubt, have the electrical system of
the house checked by a qualified
electrician.
The manufacturer cannot be held
responsible for damages caused by
the lack, or inadequacy, of an
effective grounding system.
Note to the installer
Please leave these instructions with the
consumer or the appliance.