Omron 1S Series Startup Manual page 29

Programmable multi-axis controller
Hide thumbs Also See for 1S Series:
Table of Contents

Advertisement

6
Specify the settings as shown
on the right.
Click the Accept button to apply
the settings.
Command Signal Channel
Select #x607A(Target Position), and specify the motor
control indication value for Target Position.
Amplifier Enable Signal Output Channel
Select #x6040(Controlword), and specify Controlword
for the motor output.
Amplifier Fault Signal Input Channel
Select #x6041(Statusword), and specify Statusword for
the motor input.
Primary Feedback Channel
Select #x6064(Position actual value), and specify
Position actual value for the motor control feedback.