  • Page 1 AIR CONDITIONER (MULTI TYPE) Installation Manual Indoor Unit For commercial use Model name: 1-Way Cassette Type MMU-AP0154SH1-E MMU-AP0184SH1-E MMU-AP0244SH1-E English...
  • Page 2: Table Of Contents

    Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 3 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type  Warning indications on the air conditioner unit Definition of Protective Gear When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘safety’...
  • Page 4: Precautions For Safety

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 3 – Precautions for Safety • Do not climb onto or place objects on top of the outdoor unit. You may fall or the objects may fall off of the outdoor unit and result in injury. The manufacturer shall not assume any liability for the damage caused •...
  • Page 5 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type • Install the indoor unit at least 2.5 m above the floor level since • When the air conditioner has been installed or relocated, follow the otherwise the users may injure themselves or receive electric shocks instructions in the Installation Manual and purge the air completely so if they poke their fingers or other objects into the indoor unit while the...
  • Page 6 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 5 – • Electrical wiring work shall be conducted according to law and Relocation regulation in the community and installation manual. • Only a qualified installer(*1) or qualified service person(*1) is allowed Failure to do so may result in electrocution or short circuit.
  • Page 7: Accessory Parts

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Accessory Parts CAUTION New Refrigerant Air Conditioner Installation Part name Q’ty Shape Usage • This air conditioner adopts the new HFC refrigerant (R410A) (Hand over to customers) Installation Manual This manual (For other languages that do not appear in this Installation Manual,...
  • Page 8: Selection Of Installation Place

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 7 – Selection of Installation Place  Installation under high-humidity atmosphere Avoid installing in the following places. REQUIREMENT Select a location for the indoor unit where the cool or warm air will circulate evenly. If installing an air conditioner at a place such as the following place where temperature inside of the ceiling is 30 °C or Avoid installation in the following kinds of locations.
  • Page 9: Installation

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Installation  Filter cleaning sign term setting The lighting term setup of the filter sign (Notification of filter cleaning) of the remote controller can be changed according to the condition of installation.
  • Page 10 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 9 –  Installation of hanging bolt  Installation of indoor unit Installation of hanging bolt Use M10 hanging bolts (4 pcs, to be local procure). Level gauge •...
  • Page 11: Drain Piping

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Drain Piping  Installation of ceiling panel (sold separately) REQUIREMENT CAUTION Install the ceiling panel according to Installation Manual attached with it after piping / wiring work has •...
  • Page 12 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 11 –  Drain up When the electrical and wiring work has been completed Attached hose VP25 vinyl chloride pipe Drain pipe Pour some water by following the method shown in the following figure. Then, while performing a cooling operation, band (To be local procure) connecting port...
  • Page 13: Refrigerant Piping

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Refrigerant Piping  Heat insulating process • As shown in the figure, cover the flexible hose and hose band with the attached heat insulator up to the bottom Projection margin in flaring: B (Unit: mm) of the indoor unit without gap.
  • Page 14: Electrical Connection

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 13 – Electrical Connection  Heat insulation process • Use the tightening torque levels as listed in the following table. Apply heat insulation for the pipes separately at liquid Outer dia.
  • Page 15 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type ▼ Power supply  Wiring between indoor and outdoor units 220 V – 240 V ~, 50 Hz Power supply 220 V ~, 60 Hz NOTE Power supply switch / circuit breaker or power supply wiring / fuse rating for indoor units should be selected by the An outdoor unit connected with control wiring between indoor and outdoor units wire becomes automatically the accumulated total current values of the indoor units.
  • Page 16 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 15 –  Wire connection Treating of wiring connecting port Seal the wire connecting port with heat insulator as shown on the figure. If sealing is insufficient, dewing is caused in the Electrical control box. REQUIREMENT •...
  • Page 17: Applicable Controls

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Applicable Controls  Installing indoor unit on high Each time button is pushed, indoor unit numbers in the control group change ceiling cyclically. Select the indoor unit to change ...
  • Page 18: Test Run

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 17 – Test Run  Filter sign setting  Remote controller sensor According to the installation condition, the filter sign The temperature sensor of the indoor unit senses room term (Notification of filter cleaning) can be changed.
  • Page 19: Maintenance

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Maintenance Wireless remote controller (RBC-AX32CE2) <Daily maintenance> Vacuum dust with a cleaner or clean the air When TEMPORARY button is pushed for 10 filter with water. seconds or more, “Pi!”...
  • Page 20: Troubleshooting

    Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 19 – Troubleshooting ▼ Periodic Maintenance For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner. When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended.
  • Page 21 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Check method On the wired remote controller, central control remote controller and the interface P.C. board of the outdoor unit (I/F), a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P.C. board) to display the operation is provided.
  • Page 22 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 21 – Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote controller display Auxiliary code Operation...
  • Page 23 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type Check code Wireless remote controller Outdoor unit 7-segment display Sensor block display of receiving unit Check code name Judging device Wired remote controller display Auxiliary code Operation Timer Ready...
  • Page 24 Batch alarm of general-purpose equipment control interface Differs according to error contents of unit with occurrence of alarm Group control follower unit error TCC-LINK — — (L20 is displayed.) Decrease of No. of indoor units TCC-LINK: TOSHIBA Carrier Communication Link. 45-EN 46-EN...
  • Page 25: Specifications

    336 Tadehara, Fuji-shi, Shizuoka-ken 416-8521 JAPAN Cooling Heating MMU-AP0154SH1-E 21 (5.5) MMU-AP0184SH1-E 21 (5.5) TCF holder: TOSHIBA CARRIER EUROPE S.A.S Route de Thil MMU-AP0244SH1-E 22 (5.5) 01120 Montluel FRANCE * Under 70 dBA Hereby declares that the machinery described below: Generic Denomination: Air Conditioner...
  • Page 26 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type – 25 – Warnings on Refrigerant Leakage Important Check of Concentration Limit The room in which the air conditioner is to be installed requires a design that in the event of refrigerant 2) When there is an effective opening with the adjacent room for ventilation of leaking refrigerant gas (opening gas leaking out, its concentration will not exceed a set limit.
  • Page 27 Installation Manual Installation Manual SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type 51-EN 52-EN – 26 –...
  • Page 28 EH99886601-1...