Rule Setup Submenu Choices:
Rule Setup
Displays the status of rules and lets you add new rules or modify an existing rule.
Rule 1-12
Displays the status of a rule on the right side of the menu. Rule status options:
Option
Enabled
Disabled
Invalid
Empty
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows
you to configure a rule from previously-defined alarm inputs and outputs. Once an alarm is
configured with valid inputs and outputs, it can be turned on or off (enabled or disabled)
through its configuration menu.
Rule # Choices:
Enabled
Turns the rule on or off after its inputs and outputs have been defined. YES to enable or NO to
disable (default setting).
Input
Toggles through a list of valid inputs set in the Alarm I/O Setup > Inputs Setup Menu that
defines the rule's inputs. A rule can have up to four (4) inputs.
Inputs which were set in the Inputs Setup Menu include Aux On/Off (1–99), Shot, and NONE
(default setting).
Output
Toggles through a list of valid outputs set in the Alarm I/O Setup > Outputs Setup Menu that
defines a rule's outputs.
Outputs set in the Outputs Setup Menu include Alarm Relay, Aux On/Off (1–9), Shot, OSD,
Transmit, and NONE (default setting).
Some outputs, such as Alarm Outputs 1–2 and Aux On/Off can be set to be active for a
specific duration of time as follows:
Seconds: 1–5, 10, 15, or 30
Minutes: 1–5 or 10
Latched: The alarm stays active until acknowledged.
Follows: The alarm follows the alarm rule.
Default setting: NONE
Notice!
You can include up to four (4) Input and Output events in a single rule. Each input and
output, however, must be true for the alarm's rule to be valid and enabled.
Bosch Security Systems, Inc.
Description
The rule inputs and outputs are properly defined and the rule
is turned on.
The rule inputs and outputs are defined but the rule is turned
off.
The rule has a missing or invalid input or output.
(Default setting) The rule has no inputs or outputs defined.