158.75-cell Backsheet-Glass Framed Module USER MANUAL
Models:
120cells: PD06H, PE06H, , DD06H(II), DD06H.08(II), DE06H(II),DE06H.08(II), DD06M.05(II),
DD06M.08(II) , DE06M(II), DE06M.08(II)
144cells: PD15H, PE15H, DD15H(II), DE15H(II), DD15M(II), DE15M(II)
USER MANUAL ................................................................................................................ 1
1.
INTRODUCTION FOR USER MANUAL ...................................................................... 2
1.1
DISCLAIMER ............................................................................................... 2
1.2
LIMITATION OF LIABILITY .......................................................................... 2
2.
SAFETY PRECAUTIONS............................................................................................. 2
2.1
WARNING .................................................................................................... 2
2.2
GENERAL SAFETY ..................................................................................... 2
2.3
HANDLING SAFETY .................................................................................... 2
3.
UNLOAD/TRANSPORTATION/STORAGE ............................................................... 3
3.1
MARKERS ON OUTER PACKAGING ......................................................... 3
3.2
UNLOADING WARNING ...............................................................................4
SECONDARY TRANSPORT AND WARNING ........................................ ...5
3.3
3.4
STORAGE .................................................................................................... 6
4.
UNPACKING INTRODUCTION ................................................................................. 7
4.1
UNPACKING SAFETY ................................................................................. 7
4.2
UNPACKING STEP ..................................................................................... 7
5.
SITE SELECTION ...................................................................................................... 8
6.
TILT ANGLE ............................................................................................................... 9
7.
INSTALLATION ......................................................................................................... 9
7.1
INSTALLATION SAFETY ............................................................................. 9
7.2
INSTALLATION METHOD ......................................................................... 10
7.2.1 MECHANICAL INSTALLATION AND WARNING .........................................10
7.2.2 GROUNDING ............................................................................................. 16
7.2.3 ELECTRICAL INSTALLATION .................................................................. 18
8.
INVERTER SELECTION AND COMPATIBILITY .................................................... 20
9.
MODULE MAINTENANCE FOR PV MODULE ....................................................... 20
9.1
PANEL VISION INSPECTION AND REPLACEMENT .............................. 20
9.2
CONNECTOR AND CABLE INSPECTION ................................................. 21
9.3
CLEANING ................................................................................................. 21
9.3.1 REQUIREMENTS FOR WATER QUALITY .............................................. 22
9.3.2 MODULE INSPECTION AFTER CLEANING ............................................ 22
9.3.3 TROUBLESHOOTING ............................................................................... 22
10. REPORTING TECHNICAL ISSUES or CLAIMS ..................................................... 22
Date: Nov 18th, 2020
Doc No: PS-M-0694
Ver: G
Page 1 of 23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PD06H and is the answer not in the manual?

Questions and answers

Summary of Contents for Trina Solar PD06H

  • Page 1: Table Of Contents

    158.75-cell Backsheet-Glass Framed Module USER MANUAL Models: 120cells: PD06H, PE06H, , DD06H(II), DD06H.08(II), DE06H(II),DE06H.08(II), DD06M.05(II), DD06M.08(II) , DE06M(II), DE06M.08(II) 144cells: PD15H, PE15H, DD15H(II), DE15H(II), DD15M(II), DE15M(II) USER MANUAL ........................ 1 INTRODUCTION FOR USER MANUAL ..............2 DISCLAIMER ....................2 LIMITATION OF LIABILITY ................2 SAFETY PRECAUTIONS.....................
  • Page 2: Introduction For User Manual

    Please keep this Manual for future reference. 1.1 DISCLAIMER Trina Solar reserves the rights to change this User Manual without prior notice. Failure of the customer to follow the requirements outlined in this Manual during the installation of the module will result in the invalidity of product's limited warranty.
  • Page 3: Unload/Transportation/Storage

    DO NOT damage or scratch the front or backside surfaces of the module. DO NOT scratch the output cable or bend it with force. The insulation of output cable can break and may result in electricity leakage or shock. DO NOT use water to extinguish fires of an electrical origin. DO NOT install or handle modules when they are wet or during periods of high wind.
  • Page 4: Unloading Warning

    3.1.3 Modules in carton are fragile, which must be 3.1.4 The packaging must be transported handled with care upright 3.1.5 DO NOT step on the package and module 3.1.6 The carton can be recycled 3.1.7 Modules shall be stacked as required, not 3.1.8 One module shall be handled by at exceeding the maximum number of layers printed least two persons together...
  • Page 5: Secondary Transport And Warning

    3.2.3 Store the module in a dry and ventilated place 3.2.4 DO NOT stack the modules at the project site. 3.2.5 Cover the module with waterproof material to prevent it from moisture SECONDARY TRANSPORT AND WARNING 3.3.1 remove original 3.3.2 The finished package can be transported by land, packaging if the modules require long- sea or air.
  • Page 6: Storage

    3.3.5 Only one layer stacking is only allowed 3.3.6 No transport or handling by pedi-cab as shown for transport at the project site below; 3.3.7 DO NOT transport the module with 3.3.8 DO NOT carry the modules on the back of rope as shown below: one person as shown below: STORAGE...
  • Page 7: Unpacking Introduction

    4. UNPACKING INTRODUCTION UNPACKING SAFETY For unpacking outdoors, it is prohibited to operate in rainy conditions. Because the carton will become soft and damaged after it gets wet in the rain. The stacked PV modules (hereinafter referred to as "modules") may tip over, which may cause damage or injury to personnel. For a windy site, it is necessary to pay special attention to safety.
  • Page 8: Site Selection

    Position the modules to minimize the chances of shading at any time of the day. Trina Solar recommends that the module should be installed at a working ambient temperature of - 20℃~50℃. The module's limit working ambient temperature range is from -40℃to 85℃. Maximum altitude less than or equal to 2000m .The maximum mechanical load is 5400 on the front and 2400...
  • Page 9: Tilt Angle

    INSTALLATION 7.1 INSTALLATION SAFETY Trina Solar Modules can be mounted in landscape or portrait orientation (the distance between the racking and the long side is 150-250mm), and however the impact of dirt shading the solar cells can be minimized by orienting the product in landscape. Please pay attention that 72-cell/144-cell...
  • Page 10: Installation Method

    Due to the risk of electrical shock, DO NOT perform any work if the terminals of PV module are wet. Please install immediately after you unpacking. The application level of Trina Solar module is Class C, which can be used in systems operating at greater than 50 V DC or 240 W, where general public contact access is anticipated;...
  • Page 11  The frame of each module has 4-φ9*14mm mounting holes, ideally placed to optimize the load handling capability, to secure the modules to supporting structure.  To maximize mounting longevity, Trina Solar strongly recommends the use of corrosion proof (stainless steel) fixings ...
  • Page 12 *NOTE: Need two support rails below the PV module to make sure the Mechanical load. B. Mounting with Clamps  Trina Solar has tested its modules with a number of clamps from different manufacturers, fixing bolt of at least M8. The length of clamp ≥40mm(1.57in), thickness≥ 3mm(0.12in). The clamp must overlap the module frame by at least 7mm (0.28in) but no more than 10mm (0.39in).
  • Page 13 Mechanical Load Module Safety Factor Mounting Direction Pressure 60/120 pcs Backsheet- 3600 Pa /-1600Pa Glass The crossbeam is perpendicular to the long side frame. 60/120 pcs Backsheet- +1600Pa /-1600 Pa Glass The crossbeam is perpendicular to the short side frame. 72/144 pcs Backsheet- +3600 Pa /-1600 Pa...
  • Page 14 Trina Solar warranty. φ C. Mounting with Single-axis Tracking System(4- 7*10mm mounting holes) Modules can be attached using the mounting holes on the back of the module frame, by fixing the module to the support rails with bolts.
  • Page 15 Mechanical Load Safety Module Mounting Direction Pressure factor 72/144 pcs Backsheet- +1600 Pa /-1600 Pa Glass *NOTE: The above-described distance is from the middle of the bolts to the middle of the bolts D. 2V Installation Method The single module is installed with two φ7*10mm mounting holes and two φ9*14mm mounting holes, as shown in figure 3.
  • Page 16: Grounding

     Trina Solar modules can be installed with the use of third party listed grounding devices for grounding the metallic frames of PV modules. The devices have to be installed in accordance with the grounding device manufacturer’s specified instructions.
  • Page 17 Figure 4. Tyco grounding bolt # 2058729-1 1) Wire bolt and slot 2) Mounting wash hex nut 3) Aluminum frame 4) 0.006 to 0.025 in cable 5) Hex Nut  Tyco grounding hardware comes in a package that includes the grounding bolt, mounting and grounding hex nut.
  • Page 18: Electrical Installation

    Trina Solar modules are provided with stranded copper cables with a cross sectional area of 4mm(0.006in) which are rated for 1500V DC, 90℃ and are UV resistant. All other cables used to connect the DC system should have a similar (or better) specification.
  • Page 19 The maximum voltage of the system must be less than the maximum certified voltage 1500V typically and the maximum input voltage of the inverter and of the other electrical devices installed in the system. To ensure that this is the case, the open circuit voltage of the array string needs to be calculated at the lowest expected ambient temperature for the location.
  • Page 20: Inverter Selection And Compatibility

    Cover the front surface of modules by an opaque material when repairing. Modules when exposed to sunlight generate high voltage and are dangerous. Trina Solar PV modules are equipped with bypass diodes in the junction box. This minimizes module heating and current losses.
  • Page 21: Connector And Cable Inspection

    o Isolate the impacted array string to prevent current flow before attempting to remove the module. o Disconnect the connectors of the affected module using the related disconnect tool provided by suppliers. o Replace the damaged module with a new functional module of the same type. o Check the open circuit voltage of the array string and verify that this is within 10V of the other strings to be connected in parallel.
  • Page 22: Requirements For Water Quality

    10. REPORTING TECHNICAL ISSUES or CLAIMS  Contact your installer  Contact Trina Solar after sales service team at http://customerservice.trinasolar.com/  Submit the Customer Feedback form at: http://www.trinasolar.com/ and one of our technical service representatives will contact you within 5 business days.