3.2.1 S1-1 T
HROUGH
Switches S1-1 through S1-4 are set in combination to determine the data rate
for the Async/Sync Fiber Optic Modem.
S1-1
On
Off
On
Off
On
Off
On
Off
On
Off
On
*Default
3.2.2 S1-5
S1-6: C
AND
Switches S1-5 and S1-6 are set in combination to determine the transmit clock
source for the Async/Sync Fiber Optic Modem.
S1-5
On
Off
On
*Default
ASYNC/SYNC FIBER OPTIC MODEM AND FO MODEM CARD
S1-4: D
R
ATA
ATE
Table 3-2. Data Rate Settings.
S1-2
On
On
Off
Off
On
On
Off
Off
On
On
On
S
LOCK
OURCE
Table 3-3. Clock-Source Settings.
S1-6
On
On
Off
S1-3
On
On
On
On
Off
Off
Off
Off
On
On
Off
Setting
Internal transmit clock*
Receive recover clock
External transmit clock
S1-4
Setting
On
1.2 kbps
On
1.8 kbps
On
2.4 kbps
On
3.6 kbps
On
4.8 kbps
On
7.2 kbps
On
9.6 kbps*
On
14.4 kbps
Off
19.2 kbps
Off
28.8 kbps
Off
38.4 kbps