KEYPAD DEFINITIONS

The "ON TIME" button is used to program the valve's runtime. The runtime can be
ON
set up to one hour using minute, second, and "tenths of a second" increments.
TIME
The "LOCKOUT TIME" button is used to program Lockouts. A Lockout is a specified
LOCKOUT
amount of time a fixture user must wait between actuations. A Lockout can be
TIME
programmed up to one hour using minute and second increments.
The "GLOBAL ENABLE" button is used to enable all valves that are disabled on a
GLOBAL
controller. If the programmer is connected to multiple controllers on a Versa-Link,
ENABLE
then the "GLOBAL ENABLE" button will enable all valves that are disabled on all
connected controllers. Any valves that are already enabled will remain enabled.
The "GLOBAL DISABLE" button is used to disable all valves that are enabled on a
GLOBAL
controller. If the programmer is connected to multiple controllers on a Versa-Link,
DISABLE
then the "GLOBAL DISABLE" button will disable all valves that are enabled on all
connected controllers. Any valves that are already disabled will remain disabled.
The "STATION ENABLE" button is used to enable a single valve that is disabled on
STATION
a controller.
ENABLE
The "STATION DISABLE" button is used to disable a single valve that is enabled on
STATION
a controller.
DISABLE
The "ACTUATOR MODE" button is used to configure the fixture's pushbutton to one
ACTUATOR
of the following modes:
MODE
(SC) Single Cycle -
Mode
(CI) Cycle Interrupt -
Mode
(AM) Accumulator -
Mode
www.acorneng.com
The valve runs for the programmed "ON TIME." If a lockout is
programmed, then the valve will disable until the lockout
has elapsed. Once the lockout has elapsed, the valve will
automatically return to standby mode and wait for the next
activation.
When the valve is cycled, the cycle can be interrupted by
actuating the fixture button a second time to turn the water off.
If the cycle is not interrupted, then the valve will run until the
"ON TIME" has elapsed. If a lockout is programmed, then the
valve will disable until the lockout has elapsed. Once the
lockout has elapsed, the valve will automatically return to
standby mode and wait for the next activation.
This mode is used for accumulators on an AcornVac vacuum
plumbing system. When an input signal from the accumulator is
present, the valve will open. The "ON TIME" will not begin until
the input signal is no longer present. Once the input signal is no
longer present, the valve will continue to operate until the "ON
TIME" has elapsed. Then the valve will return to standby mode.