How To Program Variable Lockout Mode - Acorn MASTER-TROL User Manual

Cpt handheld programmer
Table of Contents

Advertisement

How to program Variable Lockout Mode:

1. Program the valve for the required "ON
TIME". (See "How to change On-Time")
2. Program the valve for the required
"LOCKOUT TIME". (See "How to
change Lockout Time")
3. From the "PRESS YOUR DESIRED
FUNCTION KEY" screen, press the
"
" button.
4. If you are connected to multiple controllers,
enter the controller address with the valve
you want to program and press "ENTER".
If not, proceed to step #4.
5. Enter the station number of the valve you
want to program and press "ENTER".
6. Enter the number of Actuations you
require. (When confirmed, "A" will
represent "Actuations")
7. Enter the amount of seconds (0-59) you
require for the "Window of Time", then press
"ENTER".
8. Enter the amount of minutes (0-59) you
require for the "Window of Time", then press
"ENTER". (When confirmed, "W" will
represent "Window of Time")
9. After confirmation, the Handheld
Programmer will return to the controller/
station screen. You can change the
"Variable Lockout" for a new valve, or press
the "ESCAPE" button to change a different
feature. See "Keypad Definitions" for a
description of "
www.acorneng.com
" (Variable Lockout).
13
Technical Support: (800) 743-8259
ON
TIME
LOCKOUT
TIME

Advertisement

Table of Contents
loading

Table of Contents