Taking Gas Supply Out Of Operation; Tests; Operation - Linde C12hv Instructions For Use Manual

6-port cylinder regulator
Table of Contents

Advertisement

Available languages

Available languages

PREPARATION
1. Close cylinder valve
2. Empty pressure regulator, inlet and outlet gauge have to show „0"
3. Turn handwheel of pressure regulator anti clockwise all the way to stop, pressure regulator is closed
4. Close outlet shut o or regulating valve, if existent
5. Process Gas Purging or Discharge Process for the following version: TP, TPA, TPB
EN
EXTERNAL GAS PURGING
Purge process cylinder regulator with Inert gas Purge Valve at Inlet (TP, TPA, TPB)
A
Check, if purge gas inlet and process gas inlet are mounted properly.
B
Close all valves.
C
Close pressure regulator by turning the handwheel anti clockwise.
D
Open inert gas purge valve.
E
Close inert gas purge valve.
F
Open pressure regulator and outlet shut-o or regulating valve for very short time to release purge gas
through pressure regulator outlet.
G
Close pressure regulator and outlet shut-o or regulating valve.
Repeat point D-G 10 times for optimal result.

6.5.3. TAKING GAS SUPPLY OUT OF OPERATION

When using corrosive and/ or toxic gases with stainless steel cylinder regulator version TP, TPA, TPB,
external gas purging needs to take place before cylinder change.
BEWARE!
Consider in general when dismantling: Depressurize pressure regulator and tubing through consumer.
Inlet gauge have to show „0".
Purge with inert gas, when corrosive and / or toxic gas is used.
Consider personal safety provisions (breathing protection, eye protection, protective clothes).
Consider MAK-values (see technical rules for hazardous material, TRGS 900), choose correct respirator
fi lter.
1. Close cylinder valve
2. Depressurize pressure regulator, inlet gauge have to show "0"
3. Turn handwheel of pressure regulator anti clockwise all the way to stop
4. Close outlet shut-o valve, if existent
5. Purge or discharge process for the following version :TP, TPA, TPB, (see point 6.5.2)
Close pressure regulator by turning the handwheel anti clockwise all the way to stop.
Depressurize tubing system!
Cylinder regulator is now out of operation. Now reparation and/ or maintenance work could be done.

6.6. TESTS

After pressurizing the complete function of cylinder regulator should be tested
Check relief valve

7. OPERATION

In reference to chapter 2.1 the operation of the cylinder regulator is defi ned.
BEWARE!
Cylinder regulators must always be opened slowly and carefully to prevent pressure surges in the system
and damage to the other components!
For a brief interruption of gas removal it is su cient to close the shut o or regulating valve on the regulator.
For a longer interruption the regulator must be released from pressure by turning the handwheel anti clock-
wise. Close the cylinder valve as a safety precaution.
22/56

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

C200hv

Table of Contents