Setting The Sample Rate; Setting The Safety Stops/Deep Stops; Setting The Rgbm Values; Activation And Pre-Checks - Suunto Cobra2 User Manual

Suunto cobra2 diving instruments: user guide
Table of Contents

Advertisement

5.8.5. Setting the sample rate

The sample rate controls how often the depth, time, tank pressure, and water temperature
is stored in the memory. You can set the dive profile sample rate to 1, 10, 20, 30, or 60
seconds. The factory default setting is 20 seconds.

5.8.6. Setting the Safety Stops/Deep Stops

The Deep Stop setting allows you to choose between traditional Safety Stops or Deep
Stops. If Deep Stops are set to OFF, only the traditional Safety Stop calculation is used.
If set to ON, iterative Deep Stops will be prompted aswell. The length of the individual
Deep Stops can be set to 1 or 2 minutes.

5.8.7. Setting the RGBM values

For certain divers and diving conditions, it may be desirable to set the attenuated RGBM
mode. The selection is displayed during the DIVE mode startup. The options are full RGBM
effects (100%), and attenuated RGBM (50%).

5.9. Activation and pre-checks

This section describes how to activate the DIVE mode and explains the pre-checks that
it is highly recommended you perform before you get into the water.

5.9.1. Accessing DIVE mode

The Suunto Cobra2 has three diving modes: AIR mode for diving with standard air only,
NITROX mode for diving with oxygen enriched mixtures, and GAUGE mode for use as a
bottom timer. The OFF mode disables the DIVE mode, and allows the TIME mode to be
used underwater. The chosen dive mode is displayed when the DIVE mode is accessed,
and you can toggle between the submodes by pressing the UP/DOWN buttons.
ADJUST WITH UP AND
DOWN BUTTONS. ACCEPT
WITH SELECT BUTTON.
ADJUST WITH UP AND
DOWN BUTTONS. ACCEPT
WITH SELECT BUTTON.
ADJUST WITH UP AND
DOWN BUTTONS. ACCEPT
WITH SELECT BUTTON.
21

Advertisement

Table of Contents
loading

Table of Contents