JLAN Enable/Disable

Change the setting of jumper JPL1
to enable or disable the JLAN1 and
JLAN2 Ethernet ports. See the table
on the right for jumper settings. The
default setting is enabled
3rd Power Supply Fail Detect
Enable/Disable
The system can notify you in the event
of a power supply failure. This feature
assumes that three power supply units
are installed in the chassis with one
acting as a backup. If you only have
one or two power supply units installed,
you should disable this (the default set-
ting) with J3P to prevent false alarms.
Alarm Reset (JAR)
The system will notify you in the event
of a power supply failure. This feature
assumes that Supermicro redundant
power supply units are installed in the
chassis. If you only have a single power
supply installed, you should not connect
anything to this jumper to prevent false
alarms. See the table on the right for
jumper settings.
JLAN Enable/Disable
Jumper Settings (JPL1)
Jumper Setting
Pins 1-2
Pins 2-3
3rd Power Supply Fail
Detect Enable/Disable
Jumper Settings (J3P)
Jumper Setting
Open*
Closed
Note: This feature is only available when using
redundant Supermicro power supplies.

Alarm Reset

Jumper Settings (JAR)
Pin#
2
1
5-18
Defi nition
Enabled
Disabled
Defi nition
Disabled
Enabled
Defi nition
+5V
Ground