Installing the Chassis Rails:

Position the fixed chassis rail sections you just removed along the side of
the 6010L chassis making sure the five screw holes line up.
Note that
these two rails are left/right specific.
Screw the rail securely to the
side of the chassis (see Figure 2-2).
Repeat this procedure for the other
rail on the other side of the chassis. You will also need to attach the rail
brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab,
which serves two functions.
The first is to lock the server into place
when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the server in place when fully extended
from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2.
Installing Chassis Rails

Installing the Rack Rails:

Determine where you want to place the SuperServer 6010L in the rack.
(See Rack and Server Precautions in Section 2-3.) Position the fixed rack
rail/sliding rail guide assemblies at the desired location in the rack,
keeping the sliding rail guide facing the inside of the rack. Screw the
assembly securely to the rack using the brackets provided. Attach the
2-4