Keysight Technologies 34922A User Manual

Low frequency multiplexer modules
Hide thumbs Also See for 34922A:

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the Keysight / Agilent 34921T at our website:

Advertisement

Table of Contents
loading

Summary of Contents for Keysight Technologies 34922A

  • Page 1 sales@artisantg.com artisantg.com (217) 352-9330 | Click HERE Find the Keysight / Agilent 34921T at our website:...
  • Page 2 User Guide Keysight 34921A-34925A Low Frequency Multiplexer Modules Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4 WITHOUT NOTICE, IN FUTURE EDI- without prior agreement and written con- ment of Defense FAR Supplement TIONS. FURTHER, TO THE MAXIMUM sent from Keysight Technologies, Inc. as (“DFARS”) 227.7202, the U.S. govern- EXTENT PERMITTED BY APPLICABLE governed by United States and interna-...
  • Page 5 Safety Information Do Not Remove Instrument Cover The following general safety precau- tions must be observed during all Only qualified, service-trained person- phases of operation of this instrument. nel who are aware of the hazards Failure to comply with these precau- involved should remove instrument tions or with specific warnings or oper- covers.
  • Page 6 Safety Symbols A CAUTION denotes a hazard. It calls attention to an operating The CSA mark is a registered trade- procedure or practice, that, if not mark of the Canadian Standards Asso- correctly performed or adhered to South Korean Class A EMC Declara- ciation and indicates compliance to could result in damage to the tion.
  • Page 7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8: Table Of Contents

    34922A D-Sub Connectors........
  • Page 9 34925A Simplified Schematic for One-Wire Mode ....34925A D-Sub Connectors for One-Wired Mode ....34925T-002 Terminal Block for One-Wire Mode .
  • Page 10: Low Frequency Multiplexer Modules

    - You can connect a MUX to an external instrument, and/or switch multiple analog signals to the internal DMM. - With the 34921A, 34922A, 34923A, and the 34924A modules, you can close more than one channel in each bank simultaneously (N:1 configuration).
  • Page 11: Measurement Functions For The Multiplexer Modules

    Low Frequency Multiplexer Modules Measurement Functions for the Multiplexer Modules The MUX modules support the DMM measurement functions shown in the following table. 34922A 34922A 34923A 34923A 34924A 34925 34925A Measurement 40-ch 70-ch 40-ch 80-ch 70-ch 80-ch Function(s) Armature Armature...
  • Page 12: Operating Considerations

    Low Frequency Multiplexer Modules Operating Considerations Current Ratings See the Introduction to the Plug In Modules chapter of the 34980A Mainframe User’s Guide for detailed environmental operating conditions for the 34980A mainframe and its installed modules. That guidance sets maximum per channel current ratings at rated voltage for pollution degree 1 (dry) and pollution degree 2 (possible condensation) conditions, for all of the multiplexer modules.
  • Page 13: Scpi Programming Examples For The Multiplexer Modules

    Low Frequency Multiplexer Modules SCPI Programming Examples for the Multiplexer Modules SCPI Programming Examples for the Multiplexer Modules The programming examples below provide you with SCPI command examples to use for actions specific to the MUX modules. The slot and channel addressing scheme used in these examples follow the form sccc where s is the mainframe slot number (1 through 8) and ccc is the three-digit channel number.
  • Page 14 Low Frequency Multiplexer Modules Exampl - e - Closing and opening Analog Bus relays: The following command connects the Analog Buses to Bank 1 (via the Analog Bus relays on Bank 1) for a module in slot 3. ROUTe:CLOSe (@3911,3912,3913,3914) ROUTe:OPEN (@3911,3912,3913,3914) The Analog Bus relays (numbered s911, s912, s913, etc.) on the MUX modules are ignored if they are included in a range of channels.
  • Page 15 Low Frequency Multiplexer Modules SCPI Programming Examples for the Multiplexer Modules Configuring a Module Example - Configuring a module for 2-wire or 1-wire mode: The following command configures a MUX module in slot 4 for 1-wire mode. Because you can configure only the 34923A and 34925A MUX modules (and the 34933A matrix module) for either 2-wire or 1-wire mode, an error is generated if you send this command to a slot that does not contain one of those three modules.
  • Page 16: 34921A 40-Channel Armature Multiplexer With Low Thermal Offset

    Low Frequency Multiplexer Modules 34921A 40-Channel Armature Multiplexer with Low Thermal Offset The 34921A 40-Channel Armature Multiplexer (40-Ch Arm MUX) is divided into two banks with 20 latching armature switches (channels 1-20 and 21-40) in each. This module also offers four additional fused relays (channels 41-44) for making AC and DC current measurements with the internal DMM with no external shunts needed.
  • Page 17 Low Frequency Multiplexer Modules 34921A 40-Channel Armature Multiplexer with Low Thermal Offset - one 40-channel 2-wire MUX. You must use external wiring or connect through the internal Analog Bus relays for this configuration. For example, closing Analog Bus channels 913 and 923 connects Bank 1 and Bank 2 through ABus3.
  • Page 18: 34921A Simplified Schematic

    Low Frequency Multiplexer Modules 34921A Simplified Schematic This drawing shows two independent 20-channel 2-wire MUXes. The three-digit number assigned to each switch represents the channel number. Bank Relays: Armature latching; Analog Bus Relays: Armature non-latching Bank 1 COM 1 Analog Buses ABus1 ABus2 Current...
  • Page 19: 34921A D-Sub Connectors

    Low Frequency Multiplexer Modules 34921A 40-Channel Armature Multiplexer with Low Thermal Offset 34921A D-Sub Connectors Bank1 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is *TSIL = Temperature Sensor Interface Line. 14L 5H 20H 20L Interlock1 50-Pin D-Sub Provides thermocouple...
  • Page 20 Low Frequency Multiplexer Modules Bank 2 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. *TSIL = Temperature 50-Pin D-Sub Sensor Interface Line. 21L 22H 22L 23H 24H 24L 34H 34L 25H 25L 40H 40L Interlock 2 Male Connector Provides thermocouple...
  • Page 21: 34921T Terminal Block

    Low Frequency Multiplexer Modules 34921A 40-Channel Armature Multiplexer with Low Thermal Offset 34921T Terminal Block This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number. All modules that connect to the internal DMM are interlock protected.
  • Page 22 Low Frequency Multiplexer Modules The 34980A Product Reference CD (shipped with the instrument) contains a 34921T Wiring Log for you to document your wiring configuration for this module. You can open the wiring log file in Microsoft® Excel® or Adobe® Acrobat®...
  • Page 23: 34922A 70-Channel Armature Multiplexer

    Refer to the simplified schematic on page Using program commands or the mainframe front panel, you can control each of the channel switches individually, and thus configure the 34922A in these modes: - two independent 35-channel 2-wire MUXes. This configuration requires neither using external wiring nor connecting through the internal Analog Buses.
  • Page 24: 34922A Simplified Schematic

    Low Frequency Multiplexer Modules 34922A Simplified Schematic This drawing shows two independent 35-channel 2-wire MUXes. The three-digit number assigned to each switch represents the channel number. Bank Relays: Armature latching; Analog Bus Relays: Armature non-latching Bank 1 COM 1 Analog Buses...
  • Page 25: 34922A D-Sub Connectors

    Low Frequency Multiplexer Modules 34922A 70-Channel Armature Multiplexer 34922A D-Sub Connectors Bank 1 Bank 2 Bank 1 For orientation, the D-sub connector end of the module is facing you. 78-Pin D-Sub Male Connector Interlock1 GND 26H 15L Interlock 1 GND 32H...
  • Page 26 Low Frequency Multiplexer Modules Bank 2 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. 44L 39H 78-Pin D-Sub Male Connector 55L Interlock 2 GND 61H 50L Interlock 2 GND 67H Desc Desc Desc Desc Desc...
  • Page 27: 34922T Terminal Blocks

    Low Frequency Multiplexer Modules 34922A 70-Channel Armature Multiplexer 34922T Terminal Blocks Two terminal blocks are available to facilitate wiring connections to the 34922A module: 34922T-001 (Option 001) Terminal block with solder connectors 34922T-002 (Option 002) Terminal block with screw connectors...
  • Page 28 Low Frequency Multiplexer Modules 34922T-002 Terminal Block This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number. COM2 36 COM1 Keysight 34921A-34925A Low Frequency Multiplexer Modules User’s Guide Artisan Technology Group - Quality Instrumentation ...
  • Page 29: 34923A 40/80-Channel Reed Multiplexer

    Low Frequency Multiplexer Modules 34923A 40/80-Channel Reed Multiplexer 34923A 40/80-Channel Reed Multiplexer The 34923A 40/80-Channel Reed Multiplexer (40/80-Ch Reed MUX) is divided into two equal banks of non-latching reed switches. This module also contains eight armature Analog Bus relays (channels 911-914 and 921-924), four on each bank that can connect the bank relays to the system Analog Buses.
  • Page 30: Two-Wire Mode

    Low Frequency Multiplexer Modules Two-Wire Mode You may configure the 34923A as: - two independent 20-channel 2-wire MUXes. This configuration requires neither the use of external wiring nor connection through the internal Analog Buses. - one 40-channel, 2-wire MUX. For this configuration, you must use external wiring or connect through the internal Analog Buses.
  • Page 31 Low Frequency Multiplexer Modules 34923A 40/80-Channel Reed Multiplexer Analog Bus relay closed you can close up to a maximum of 39 channel relays. If you try to close more than the allowed number of channels, you will receive an error message. Keysight 34921A-34925A Low Frequency Multiplexer Modules User’s Guide Artisan Technology Group - Quality Instrumentation ...
  • Page 32: 34923A Simplified Schematic For Two- Or Four-Wire Mode

    Low Frequency Multiplexer Modules 34923A Simplified Schematic for Two- or Four-Wire Mode This drawing shows two independent 20-channel 2-wire MUXes. To change configuration modes, use the SYSTem:MODule:WIRE:MODE command. The three-digit number assigned to each switch represents the channel number. Bank Relays: Reed non-latching; Analog Bus Relays: Armature non-latching Bank 1 COM 1...
  • Page 33: 34923A D-Sub Connectors For Two- Or Four-Wire Mode

    Low Frequency Multiplexer Modules 34923A 40/80-Channel Reed Multiplexer 34923A D-Sub Connectors for Two- or Four-Wire Mode Bank 1 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. 50-Pin D-Sub Male Connector 14L 5H 20H 20L Interlock1 Reserved 11H 11L...
  • Page 34 Low Frequency Multiplexer Modules Bank 2 Bank 1 Bank 2 For orientation, the D-sub connecto end of the module is facing you. 50-Pin D-Sub 21L 22H 22L 23H 24H 24L 34H 34L 25H 25L 40H 40L Interlock 2 Male Connector Reserved 31H 31L 27H 27L 37H 33H 33L...
  • Page 35: 34923T-001 Terminal Block For Two-Wire Or Four-Wire Mode

    Low Frequency Multiplexer Modules 34923A 40/80-Channel Reed Multiplexer 34923T-001 Terminal Block for Two-Wire or Four-Wire Mode This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number.
  • Page 36: 34923A Simplified Schematic For One-Wire Mode

    Low Frequency Multiplexer Modules 34923A Simplified Schematic for One-Wire Mode This drawing shows two independent 40-channel 1-wire MUXes. To change configuration modes, use the SYSTem:MODule:WIRE:MODE command. The three-digit number assigned to each switch represents the channel number. Bank Relays: Reed non-latching; Analog Bus Relays: Armature non-latching Bank 1 COM 1...
  • Page 37: 34923A D-Sub Connectors For One-Wire Mode

    Low Frequency Multiplexer Modules 34923A 40/80-Channel Reed Multiplexer 34923A D-Sub Connectors for One-Wire Mode Bank 1 Bank 2 Bank 1 For orientation, the D-sub connector end of the module is facing you. Interlock1 50-Pin D-Sub Male Connector Reserved 30 Interlock 1 Reserved Desc Desc...
  • Page 38 Low Frequency Multiplexer Modules Bank 2 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. 50-Pin D-Sub Interlock 2 Male Connector Reserved 70 Interlock 2 Reserved Desc Desc Desc Desc Desc COM2 H COM2 L Interlock Interlock...
  • Page 39: 34923T-002 Terminal Block For One-Wire Mode

    Low Frequency Multiplexer Modules 34923A 40/80-Channel Reed Multiplexer 34923T-002 Terminal Block for One-Wire Mode This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number All modules that connect to the internal DMM are interlock protected.
  • Page 40 Low Frequency Multiplexer Modules Keysight 34921A-34925A Low Frequency Multiplexer Modules User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 41: 34924A 70-Channel Reed Multiplexer

    Low Frequency Multiplexer Modules 34924A 70-Channel Reed Multiplexer 34924A 70-Channel Reed Multiplexer The high-density 34924A 70-Channel Reed Multiplexer (70-Ch Reed MUX) is divided into two banks with 35 non-latching reed switches (channels 1-35 and 36-70) in each. This module also contains eight armature Analog Bus relays (channels 911-914 and 921-924), four on each bank that can connect the bank relays to the system Analog Buses.
  • Page 42 Low Frequency Multiplexer Modules This module is interlock protected, which means whenever the D-sub connector end of the modules is exposed, the Analog Bus relays immediately open and disconnect from the Analog Bus. For more information, see “Safety Interlock” page 11. Lifetime of relays is severely degraded as current or voltage goes up.
  • Page 43: 34924A Simplified Schematic

    Low Frequency Multiplexer Modules 34924A 70-Channel Reed Multiplexer 34924A Simplified Schematic This drawing shows two independent 35-channel 2-wire MUXes. The three-digit number assigned to each switch represents the channel number. Bank relays: Reed non-latching; Analog Bus relays: Armature non-latching Bank 1 COM 1 100...
  • Page 44: 34924A D-Sub Connectors

    Low Frequency Multiplexer Modules 34924A D-Sub Connectors Bank 1 Bank 2 Bank 1 For orientation, the D-sub connector end of the module is facing you. 78-Pin D-Sub Male Connector Interlock1 GND 26H 15L Interlock 1 GND 32H Desc Desc Desc Desc Desc Desc...
  • Page 45 Low Frequency Multiplexer Modules 34924A 70-Channel Reed Multiplexer Bank 2 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. 44L 39H 78-Pin D-Sub Male Connector 55L Interlock 2 GND 61H 50L Interlock 2 GND 67H Desc Desc...
  • Page 46: 34924T Terminal Blocks

    Low Frequency Multiplexer Modules 34924T Terminal Blocks Two terminal blocks are available to facilitate wiring connections to the 34924A module: 34924T-001 (Option 001) Terminal block with solder connectors 34924T-002 (Option 002) Terminal block with screw connectors The 34980A Product Reference CD (shipped with the instrument) contains a 34924T Wiring Log for you to document your wiring configuration for this module.
  • Page 47 Low Frequency Multiplexer Modules 34924A 70-Channel Reed Multiplexer 34924T-002 Terminal Block This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number. COM2 36 COM1 Keysight 34921A-34925A Low Frequency Multiplexer Modules User’s Guide...
  • Page 48: 34925A 40/80-Channel Optically-Isolated Fet Multiplexer

    Low Frequency Multiplexer Modules 34925A 40/80-Channel Optically-Isolated FET Multiplexer The 34925A 40/80-Channel Optically-Isolated FET Multiplexer (40/80-Ch FET MUX) module is a high-speed and high-density FET MUX for high throughput production test. This module is divided into two equal banks of non-latching FET switches.
  • Page 49: Four-Wire Mode

    Low Frequency Multiplexer Modules 34925A 40/80-Channel Optically-Isolated FET Multiplexer Four-Wire Mode - You may configure the 34925A as a single 20-channel 4-wire MUX. This configuration requires using neither external wiring nor connecting through the internal Analog Buses. For 4-wire resistance measurements, the instrument automatically pairs channel n on Bank 1 (source) with channel n+20 on Bank 2 (sense) to provide these connections.
  • Page 50 Low Frequency Multiplexer Modules - using the *RST command. This command resets the mainframe and all installed modules to the Factory configuration. This affects all installed modules. - cycling system power. This affects all installed modules. If the overvoltage situation is not resolved, clearing the overvoltage will result in a new overvoltage event occurring immediately.
  • Page 51: 34925A Simplified Schematic For Two- Or Four-Wire Mode

    Low Frequency Multiplexer Modules 34925A 40/80-Channel Optically-Isolated FET Multiplexer 34925A Simplified Schematic for Two- or Four-Wire Mode This drawing shows two independent 20-channel 2-wire MUXes. To change configuration modes, use the SYSTem:MODule:WIRE:MODE command The three-digit number assigned to each switch represents the channel number.
  • Page 52: 34925A D-Sub Connectors For Two- Or Four-Wire Mode

    Low Frequency Multiplexer Modules 34925A D-Sub Connectors for Two- or Four-Wire Mode Bank 2 Bank 1 Bank 1 For orientation, the D-sub connector end is facing you. 50-Pin D-Sub 14L 5H 20H 20L Interlock1 Male Connector Reserved 11H 11L 13H 13L 19H 19L 15H 15L Interlock 1 GND 6H 16H 16L 12H 12L...
  • Page 53 Low Frequency Multiplexer Modules 34925A 40/80-Channel Optically-Isolated FET Multiplexer Bank 2 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. 21L 22H 22L 23H 24H 24L 34H 34L 25H 25L 40H 40L Interlock 2 50-Pin D-Sub Male Connector Reserved 31H 31L 27H...
  • Page 54: 34925T-001 Terminal Block For Two-Wire Or Four-Wire Mode

    Low Frequency Multiplexer Modules 34925T-001 Terminal Block for Two-Wire or Four-Wire Mode This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number. - All modules that connect to the internal DMM are interlock protected.
  • Page 55 Low Frequency Multiplexer Modules 34925A 40/80-Channel Optically-Isolated FET Multiplexer 34925A Simplified Schematic for One-Wire Mode This drawing shows two independent 40-channel, 1-wire MUXes. To change configuration modes, use the SYSTem:MODule:WIRE:MODE command The three-digit number assigned to each switch represents the channel number.
  • Page 56 Low Frequency Multiplexer Modules 34925A D-Sub Connectors for One-Wired Mode Bank 1 Bank 2 Bank 1 For orientation, the D-sub connector end of the module is facing you. Interlock1 50-Pin D-Sub Male Connector Reserved 30 Interlock 1 Desc Desc Desc Desc Desc COM1 H...
  • Page 57 Low Frequency Multiplexer Modules 34925A 40/80-Channel Optically-Isolated FET Multiplexer Bank 2 Bank 1 Bank 2 For orientation, the D-sub connector end of the module is facing you. 50-Pin D-Sub Interlock 2 Male Connector Reserved 70 Interlock 2 Desc Desc Desc Desc Desc COM2 H...
  • Page 58 Low Frequency Multiplexer Modules 34925T-002 Terminal Block for One-Wire Mode This terminal block with screw-type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number. All modules that connect to the internal DMM are interlock protected.
  • Page 59 34923T Option 001 external reference 34923T Option 002 connector pinouts programming examples 34924T Option 001 34921A simplified schematic 34924T Option 002 34922A temperature sensor 34925T Option 001 34923A terminal block 34925T Option 002 34924A valid measurement 34925A functions wiring log...
  • Page 60 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 61 This information is subject to change without notice © Keysight Technologies 2016 Edition 2 January 2016 Published in USA 34980-90021 www.keysight.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...

This manual is also suitable for:

34921a34923a34924a34925a

Table of Contents