This product, including software and docu- mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
Page 3
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the 2027R-AR24NV. Installation and maintainance should be performed by experienced technicians only. The 2027R-AR24NV is a high-end server based on the SC216BAC-R920LPB 2U chassis and the X9DRH-iF-NV dual processor serverboard.
Page 4
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DRH-iF-NV serverboard, includ- ing the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi g- uring the serverboard.
Server Chassis Features ................1-3 System Power ....................1-3 Hard Drives ..................... 1-3 Front Control Panel ..................1-3 Cooling System ....................1-3 Contacting Supermicro ..................1-6 Chapter 2 Server Installation Overview ......................2-1 Unpacking the System ..................2-1 Preparing for Setup ..................2-1 Choosing a Setup Location ................
Page 7
Table of Contents Optional Quick Installation Method ..............2-9 Chapter 3 System Interface Overview ......................3-1 Control Panel Buttons ..................3-1 Control Panel LEDs ..................3-1 Drive Carrier LEDs ..................3-3 Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements ............4-1 Warning Defi...
SC216BAC-R920LPB 2U server chassis and the X9DRH-iF-NV dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com). In addition to the serverboard and chassis, various hardware components have been included with the 2027R-AR24NV, as listed below: •...
The X9DRH-iF-NV supports single or dual Intel® E5-2600 Series (Socket R) pro- cessors in LGA 2011 sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com). Memory The X9DRH-iF-NV has sixteen DIMM slots that can support up to 512 GB of ECC registered/unbuffered DDR3-1600/1066/800 memory as well as Non-Volatile memory modules (NVDIMM) from vendors that use the ADR method of triggering.
Chapter 1: Introduction Graphics Controller The X9DRH-iF-NV features an integrated Matrox G200eW video controller. The G200eW is a 2D/3D/video accelerator chip with a 128-bit core. Server Chassis Features The SC216BAC-R920LPB is a 2U rackmount form factor chassis designed to be used with industry standard 19"...
Page 12
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Figure 1-1. Chipset Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. #H-2 #H-1 #D-2 #G-2 #G-1 #C-2 #C-1 #F-2 #F-1 #B-2 #B-1 #E-2 #A-2 #E-1 E5-2600 E5-2600 #A-1 8 SNB CORE 8 SNB CORE...
Page 13
Chapter 1: Introduction Figure 1-2. X9DRH-iF-NV Layout USB2/3 USB0/1 COM1 LAN CTRL BMC CTRL FAN5 KB/MS IPMI_LAN LAN1 LAN2 COM2 CLOSE 1st CPU2 OPEN 1st Battery T-SGPIO1 BIOS X9DRH-7F/iF Rev. 1.01 JITP0 JBT1 Intel IO Hub LEDS1 CLOSE 1st CPU1 LSI SAS CTRL OPEN 1st...
Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your 2027R-AR24NV up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl...
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Rack Mounting Instructions This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided. You should also refer to the installation instructions that came with the rack unit you are using.
Chapter 2: Server Installation Locking Tabs Each inner rail has a locking tab. This tab locks the chassis into place when installed and pushed fully into the rack. These tabs also lock the chassis in place when fully extended from the rack. This prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Inner Rails Figure 2-3. Installing the Inner Rails Figure 2-4. Inner Rails Installed on the Chassis (The chassis above are an example only. Actual chassis may differ slightly) Installing The Inner Rails on the Chassis Installing the Inner Rails 1.
Chapter 2: Server Installation Figure 2-5. Extending and Releasing the Outer Rails Installing the Outer Rails on the Rack Installing the Outer Rails 1. Press upward on the locking tab at the rear end of the middle rail. 2. Push the middle rail back into the outer rail. 3.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Ball-Bearing Shuttle Figure 2-6. Installing into a Rack Standard Chassis Installation Installing the Chassis into a Rack 1. Confi rm that the inner rails are properly installed on the chassis. 2. Confi rm that the outer rails are correctly installed on the rack. 3.
Chapter 2: Server Installation Optional Quick Installation Method The following quick installation method may be used to install the chassis onto a rack. Installing the Chassis into a Rack 1. Install the whole rail assembly onto the rack as described on page 6-7. 2.
Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi...
Page 26
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Power Fail Indicates a power supply module has failed. The second power supply module will take the load and keep the system running but the failed module will need to be replaced. Refer to Chapter 6 for details on replacing the power supply. This LED should be off when the system is operating normally.
Chapter 3: System Interface Indicates IDE channel activity. On the 2027R-AR24NV, this LED indicates hard and/ or DVD-ROM drive activity when fl ashing. Power Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. Drive Carrier LEDs Each drive carrier has two LEDs.
Only certifi ed technicians should attempt to install or confi gure components. Read this appendix in its entirety before installing or confi guring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Defi nition Warning! This warning symbol means danger.
Page 30
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
UPER TORAGE YSTEM 2027R-AR24NV User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Page 35
Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi...
Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual אזור עם גישה מוגבלת !אזהרה יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת .('כלי אבטחה בלבד )מפתח, מנעול וכד ﻣﺤﻈﻮﺭﺓ ﻣﻨﺎﻁﻖ ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ ﺗﺨﺼﻴﺺ ﺗﻢ ،ﺃﺩﺍﺓ ﺧﺎﺻﺔ ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ ﻓﻘﻂ...
Page 39
Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben.
Chapter 4: Warning Statements for AC Systems ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ ﺑﻮﺣﺪﺍﺕ ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ ﺠﻬﺎﺯ ﺍﻟ ﻳﻜﻮﻥ ﻟﻬﺬﺍ ﻗﺪ ﺍﻟﻜﻬﺮﺑﺎء ﻋﻦ ﻮﺣﺪﺓ ﺍﻟ ﻟﻌﺰﻝ ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ ﻳﺠﺐ ﺇﺯﺍﻟﺔ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. תיאום חוקי החשמל הארצי !אזהרה הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים התקנת ﺍﻟﻤﺘﻌﻠﻘﺔ ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ ﻘﻮﺍﻧﻴﻦ ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ...
UPER TORAGE YSTEM 2027R-AR24NV User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
Page 45
Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi ed cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター...
Page 47
Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi és qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have fi...
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Connecting Cables The cables listed below should already be connected to the serverboard. These include the data cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the fl...
Chapter 5: Advanced Serverboard Setup Figure 5-1. Control Panel Header Pins Ground x (Key) x (Key) Power On LED HDD LED NIC1 LED NIC2 LED OH/Fan Fail LED Power Fail LED Ground Reset (Button) Ground Power (Button) I/O Ports The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below for the colors and locations of the various I/O ports.
CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro web site for updates on CPU support. Installing an LGA2011 Processor Press down on the lever labeled 'Close 1st' 1.
Page 53
Chapter 5: Advanced Serverboard Setup 3. With the lever labeled 'Close 1st' fully retracted, gently push down on the 'Open 1st' lever to open the load plate. Lift the load plate to open it completely. Gently push 4. Using your thumb and the index down to pop the load plate fi...
Page 54
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Warning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly, do not force it as it may damage your CPU. Instead, open the load plate again and double-check that the CPU is aligned properly.
Chapter 5: Advanced Serverboard Setup Installing a CPU Heatsink 1. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism. 2. Screw in two diagonal screws (i.e. the #1 and the #2 screws) until just snug (do not over-tighten the screws, which may damage the CPU.) 3.
(NVDIMM) from vendors, whicht use the ADR method of triggering. Use memory modules of the same type and speed. See the following tables for memory installation. Please refer to the Supermicro web site for possible updates to sup- ported memory.
Chapter 5: Advanced Serverboard Setup For memory to work properly, populate according to the tables below. Processors and their Corresponding Memory Modules CPU# Corresponding DIMM Modules CPU 1 DIMMA1 DIMMB1 DIMMC1 DIMMD1 DIMMA2 DIMMB2 DIMMC2 DIMMD2 CPU2 DIMME1 DIMMF1 DIMMG1 DIMMH1 DIMME2 DIMM F2...
Page 58
UPER TORAGE YSTEM 2027R-AR24NV User's Manual UDIMM Memory Support Ranks Per DIMM & Memory Capacity Data Width Per DIMM (Note 1) SRx8 Non-ECC DRx8 Non-ECC SRx16 Non-ECC 512MB SRx8 ECC DRx8 ECC Note: 1Gb/2Gb/4Gb DRAMs are supported; however, only 2Gb and 4Gb DRAMs are validated.
Chapter 5: Advanced Serverboard Setup Adding PCI Add-On Cards The 2027R-AR24NV can accommodate four low-profi le PCI add-on cards. Installing an Add-on Card 1. Begin by removing the shield for the PCI slot you wish to populate. 2. Fully seat the card into the slot, pushing down with your thumbs evenly on both sides of the card.
Page 64
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Onboard Buzzer (Internal Speaker) T-SGPIO1 Serial Link General_Purpose IO Headers (used in conjunc- tion with I-SATA 0~3) T-SGPIO2 Serial Link General_Purpose IO Header (used in conjunc- tion with I-SATA 4/5) T-SGPIO-S Serial Link General_Purpose IO Header (used in conjunc- tion with S-SATA 0~3) USB 0/1, 2/3 Back Panel USB 0/1, 2/3...
Chapter 5: Advanced Serverboard Setup Connector Defi nitions ATX Power 24-pin Connector Pin Defi nitions Pin# Defi nition Pin # Defi nition Power Connectors +3.3V +3.3V -12V +3.3V A 24-pin main power supply connector (J22) and two 8-pin power connectors PS_ON (JPWR1/JPWR2) are provided on the serverboard.
Page 66
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Power Fail LED PWR Fail LED Pin Defi nitions (JF1) The Power Fail LED connection is Pin# Defi nition located on pins 5 and 6 of JF1. Re- fer to the table on the right for pin Ground defi...
Page 67
Chapter 5: Advanced Serverboard Setup Power On LED Power LED Pin Defi nitions (JF1) The Power On LED connector is lo- Pin# Defi nition cated on pins 15 and 16 of JF1 (use 5V Stby JLED for a 3-pin connector). This Control connection is used to provide LED indication of power being supplied to...
Page 68
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Chassis Intrusion Chassis Intrusion The Chassis Intrusion header is des- Pin Defi nitions ignated JL1. Attach an appropriate Pin# Defi nition cable from the chassis to inform you Intrusion Input of a chassis intrusion when the chas- Ground sis is opened Internal Buzzer (SP1)
Page 69
Chapter 5: Advanced Serverboard Setup Standby Power Pin Defi nitions Standby Power Pin# Defi nition The Standby Power header is located +5V Standby at JSTBY1 on the serverboard. See Ground the table on the right for pin defi ni- Wake-up tions.
Page 70
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Universal Serial Bus (USB) Backplane USB FP USB (4/5, 6) (USB 0/1, 2/3) Pin Defi nitions Four Universal Serial Bus ports (USB Pin Defi nitions USB 4, 6 USB 5 0/1, 2/3) are located on the I/O back Pin# Defi...
Chapter 5: Advanced Serverboard Setup Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used Connector to choose between optional settings. Pins Jumpers create shorts between two pins to change the function of the con- nector.
Page 72
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Watch Dog Enable/Disable Jumper JWD controls the Watch Dog function. Watch Dog is a system moni- tor that can reboot the system when a Watch Dog Jumper Settings software application hangs. Jumping Jumper Setting Defi...
Chapter 5: Advanced Serverboard Setup 5-10 Onboard Indicators LAN LEDs The Ethernet ports have two LEDs. JLAN1/2 LED On each port, the yellow LED fl ashes (Connection Speed Indicator) to indicate activity while the other LED LED Color 1 Gb Ports may be green, amber or off to indicate NC or 10 Mb/s the speed of the connection.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual 5-11 SATA Ports SATA Ports SATA Port There are ten Serial ATA Ports (I- Pin Defi nitions SATA0~I-SATA 5) located on the Pin# Defi nition Defi nition serverboard, including eight SATA2 Ground ports (I-SATA2~5, S-SATA0~3) and Ground two SATA3 ports (I-SATA0~1).
Chapter 5: Advanced Serverboard Setup 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
UPER TORAGE YSTEM 2027R-AR24NV User's Manual SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system.
Chapter 5: Advanced Serverboard Setup Figure 5-7. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/soft- ware/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC216BAC-R920LPB chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Figure 6-1. Front and Rear Chassis Views Control Panel Hard Drives (24) Power Supplies (2) 5 Low-profi le PCI Slots I/O Ports (see Figure 5-2) IT Mode Disk Controllers (LSI 3008) Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Chapter 6: Advanced Chassis Setup Removing the Chassis Cover Remove this screw (if necessary) Release Tab Figure 6-2. Removing the Chassis Cover Removing the Chassis Cover You may need to gain access to the inside of the server to perform various main- tenance tasks.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual System Cooling System Fans Three 8-cm hot-swap chassis fans provide the cooling for the 2027R-AR24NV. It is very important that the chassis top cover is properly installed in order for the cooling air to circulate properly through the chassis and cool the components. See Figure 6-3.
Chapter 6: Advanced Chassis Setup Figure 6-3. Replacing System Cooling Fans Air Shrouds Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC216 chassis air shrouds do not require screws for installation. Installing the Air Shrouds in the Chassis Installing the Main Air Shroud 1.
Page 84
UPER TORAGE YSTEM 2027R-AR24NV User's Manual An additional air shroud is required for high-powered CPUs, to provide extra cooling. Install the additional air shroud if necessary. Installing the Additional Air Shroud 1. Remove the left side break-away piece of the main air shroud. 2.
1. Press the release button on the drive tray. This extends the drive bay handle. 2. Use the handle to pull the tray out of the chassis. Warning: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web...
Page 86
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Figure 6-5. Removing a Hard Drive Carrier Note: Regardless of how many hard drives are installed, all drive carriers must remain in the drive bays to maintain proper airfl ow. Warning: Use caution when working around the backplane. Do not touch the back- plane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper airfl...
Page 87
Chapter 6: Advanced Chassis Setup Figure 6-6. Mounting a SATA Drive in a Carrier Installing a Hard Drive into a Drive Carrier 1. Insert a drive into the carrier with the PCB side facing down and the connec- tor end toward the rear of the carrier. 2.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Power Supply The 2027R-AR24NV chassis has two redundant 920 Watt power supplies. The power modules are hot-swappable, enabling them to be changed without powering down the system. These power supplies are auto-switching capable, allowing them to automatically sense and operate at a 100v to 240v input voltage.
Page 89
Chapter 6: Advanced Chassis Setup Changing the Power Supply 1. Determine which power supply needs to be replaced and unplug the power cord to that module. 2. Push the release tab (on the back of the power supply) as illustrated, to release the power module from the chassis.
Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup utility for the X9DRH-7F/-iF/-7TF/-iTF/ NV. It also provides the instructions on how to navigate the AMI BIOS Setup util- ity screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.
<Delete> at the appropriate time during system boot. Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Re- covery User Guide posted @http://www.supermicro.com/support/manuals/. Starting the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
Page 93
Chapter 7: BIOS The AMI BIOS main menu displays the following information: System Time/System Date Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard and press <Enter>.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Advanced Setup Confi gurations Use the arrow keys to select Advanced and press <Enter> to access the following submenu items: Boot Feature Quiet Boot Set this value to allow the bootup screen options to be modifi ed between POST messages or the OEM logo.
Page 95
Chapter 7: BIOS Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks.
Page 96
UPER TORAGE YSTEM 2027R-AR24NV User's Manual • CPU Stepping • Maximum CPU Speed • Minimum CPU Speed • Processor Cores • Intel HT(Hyper-Threading) Technology • Intel VT-x (Virtualization) Technology • L1 Data Cache • L1 Code Cache • L2 Cache •...
Page 97
Chapter 7: BIOS Execute-Disable Bit Capability (Available if supported by the OS & the CPU) Set to Enabled to enable the Execute Disable Bit, which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from fl...
Page 98
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Power Technology Select Energy Effi cient to support power-saving mode. Select Custom to custom- ize system power settings. Select Disabled to disable power-saving settings. The options are Disable, Energy Effi cient and Custom. If Custom is selected, the following options become available: EIST EIST (Enhanced Intel SpeedStep Technology) allows the system to auto-...
Page 99
Chapter 7: BIOS Package C State Limit If set to Auto, the AMI BIOS will automatically set the limit on the C-State package register. The options are C0, C2, C6, C7, and No Limit. Energy/Performance Bias Use this feature to select an appropriate fan setting to achieve maximum system performance (with maximum cooling) or maximum energy effi...
Page 100
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Chipset Confi guration North Bridge This feature allows the user to confi gure the settings for the Intel North Bridge. IOH (IO Hub) Confi guration Intel ® VT-d Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to the VMM (Virtual Machine Monitor) through the DMAR ACPI Tables.
Page 101
Chapter 7: BIOS IOU2 - PCIe Port This feature allows the user to set the PCI-Exp bus speed between IOU2 and PCIe port. The default setting is x8x8. Slot 2 Link Speed Select GEN1 to enable PCI-Exp Generation 1 support for Slot 2 Port. Select GEN2 to enable PCI-Exp Generation 2 support for Slot 2 Port.
Page 102
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Current QPI Link Frequency This item displays the current frequency of the QPI Link. Isoc Select Enabled to enable Isochronous support to meet QoS (Quality of Service) requirements. This feature is especially important for virtualization technology. The options are Disabled and Enabled.
Page 103
Chapter 7: BIOS DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is indicated in the system specifi cation. The options are Auto, Force DDR3- 800, Force DDR3-1066, Force DDR3-1333, Force DOR3-1600 and Force SPD. Channel Interleaving This feature selects from the different channel interleaving methods.
Page 104
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Thermal Throttling Throttling improves reliability and reduces power consumption in the proces- sor via automatic voltage control during processor idle states. The options are Disabled and CLTT (Closed Loop Thermal Throttling). South Bridge This feature allows the user to confi...
Page 105
Chapter 7: BIOS SATA Confi guration When this submenu is selected, the AMI BIOS automatically detects the presence of IDE or SATA devices and displays the following items. SATA Port0~SATA Port5 The AMI BIOS displays the status of each SATA port as detected by the BIOS. SATA Mode Use this feature to confi...
Page 106
UPER TORAGE YSTEM 2027R-AR24NV User's Manual RAID Mode The following items are displayed when RAID Mode is selected: Port 0~5 Hot Plug Select Enabled to enable hot-plug support for a port specifi ed by the user. The options are Enabled and Disabled. ...
Page 107
Chapter 7: BIOS PERR# Generation Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus Signal Error Event. The options are Enabled and Disabled. SERR# Generation Select Enabled to allow a PCI device to generate a SERR number for a PCI Bus Signal Error Event.
Page 108
UPER TORAGE YSTEM 2027R-AR24NV User's Manual VGA Priority Use this feature to specify which graphics controller to be used as the primary boot device. The options are Onboard and Offboard (VGA). Network Stack Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unifi ed Extensible Firmware Interface) for network stack support.
Page 109
Chapter 7: BIOS Device Settings This item displays the settings of Serial Port 2. Change Settings This option specifi es the base I/O port address and the Interrupt Request address of Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources.
Page 110
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec- tion. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600, and 115200 (bits per second).
Page 111
Chapter 7: BIOS Resolution 100x31 Select Enabled for extended-terminal resolution support. The options are Dis- abled and Enabled. Legacy OS Redirection Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25. Putty Keypad Use this feature to select function key and keypad setting on Putty.
Page 112
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Flow Control This feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer overfl ow. Send a "Stop" signal to stop send- ing data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty.
Page 113
Chapter 7: BIOS TPM State Select Enabled to enable TPM security settings to improve data integrity and network security. The options are Disabled and Enabled. Pending Operation Use this item to schedule an operation for the security device. The options are None, Enable Take Ownership, Disable Take Ownership, and TPM Clear.
Page 114
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Intel TXT (LT-SX) Dependencies This feature displays the features that need to be enabled for the Intel Trusted Execution Technology to work properly in the system. VT-d Support: Intel Virtualization Technology with Direct I/O support VT Support: Intel Virtualization Technology support TPM Support: Trusted Platform support TPM State: Trusted Platform state...
Chapter 7: BIOS Event Logs Use this menu to confi gure Event Log settings. Change SmBIOS Event Log Settings Enabling/Disabling Options Smbios Event Log Change this item to enable or disable all features of the Smbios Event Logging during boot. The options are Enabled and Disabled. Runtime Error Logging Support Change this item to enable or disable runtime error logging.
Page 116
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Erasing Settings Erase Event Log Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which is completed before a event logging is initialized upon system reboot. The options are No, Yes, Next reset, and Yes, Every reset. When Log is Full This option automatically clears the Event Log memory of all messages when it is full.
Chapter 7: BIOS IPMI Use this menu to confi gure Intelligent Platform Management Interface (IPMI) set- tings. System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup. The options are Enabled and Disabled. Erasing Settings Erase SEL Select 'Yes, On next reset' to erase all system event logs upon next system reboot.
Page 118
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Log EFI Status Codes Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error Codes or Progress Codes. The options are disabled an Enabled. Note: After making changes on a setting, be sure to reboot the system for the changes to take effect.
Chapter 7: BIOS Boot This menu allows the user to confi gure the following boot settings for the system. Boot Option Priorities Boot Option #1/ Boot Option #2/ Boot Option #3 Use this feature to specify the sequence of boot device priority. Network Device BBS Priorities This option sets the order of the legacy network devices detected by the mother- board.
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Security This menu allows the user to confi gure the following security settings for the system. Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long.
Chapter 7: BIOS Save & Exit This menu allows the user to confi gure the Save and Exit settings for the system. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration, and reboot the computer. Select Discard Changes and Exit, and press <Enter>.
Page 122
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Discard Changes Select this feature and press <Enter> to discard all the changes and return to the BIOS setup. When the dialog box appears, asking you if you want to load previ- ous values, select Yes to load the values previous saved, or select No to keep the changes you've made so far.
Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
Appendix B: System Specifi cations Appendix B System Specifi cations Processors Single or dual Intel® E5-2600 Series (Socket R) processors in LGA 2011 sockets (both CPUs must be of the same type) Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C602 chipset BIOS...
Page 126
UPER TORAGE YSTEM 2027R-AR24NV User's Manual Serverboard X9DRH-iF-NV Dimensions: 12 x 13 in (305 x 330 mm) Chassis SC216BAC-R920LPB, 2U rackmount Dimensions: (WxHxD) 17.2 x 3.5 x 24.8 in. (437 x 89 x 630 mm) Weight Gross: 61 lbs. (27.7 kg.) System Cooling Three 8-cm hot-plug system fans System Input Requirements...
Page 127
Appendix B: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3- 3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials:...
Page 128
YSTEM 2027R-AR24NV User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...