Ii.ddescription Of Test Runs; Ii.dsummary Of Other Data - Drolet DB03105 Installation And Operation Manual

Hide thumbs Also See for DB03105:
Table of Contents

Advertisement

Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM
Test report #103124842MTL-001 (7 of 15)
Stove Builder International Inc.
Project No. G103124842
II.C•
SUMMARY•OF•TEST•RESULTS• •
The appliance tests resulted in the following performance:
II.D• DESCRIPTION•OF•TEST•RUNS•
RUN #1 (6 July 2017) Air control set at the targeted burn rate, burn time was 430
minutes with a category medium burn rate of 1.3 kg/hr. Took 1 minute to set the load
and let the door ajar for 5 minutes, and then closed. The air control was open for 16
minutes or when 15% of the load weight has been consumed, and then set at the
targeted burn rate. The fan energized and set at low speed at 30 minutes.
RUN #2 (7 July 2017) Air control set at the targeted burn rate, burn time was 490
minutes with a category Low burn rate of 1.1 kg/hr. Load within 1 minute let the door
ajar for 5 minutes, and then closed. The air control was open for 16 minutes or when
15% of the load weight has been consumed, and then set at the targeted burn rate.
The fan was energized and set at low speed at 30 minutes.
RUN #3 (13 July 2017) Air control set fully opened, burn time was 280 minutes with a
category High burn rate of 2.6 kg/hr. The door was open for 5 minutes, then closed.
The air control was fully opened. Fan was energized and set at full speed. For this
run, emission collection started with a cold unit.
confirmation.
II.D• SUMMARY•OF•OTHER•DATA
TABLE•1.•-•EMISSIONS•
Run
Test
Number
Date
6
1
July
2017
2
7
Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy
Particulate Emissions: 1.54 g/hr
Carbon Monoxide Emissions: 89 g/hr
Heating Efficiency: 69% (Higher Heating Value Basis)
Particulate
Burn Rates
Emission
(kg/hr)(Dry)
Rate
(g/hr)
1.3
0.83
1.1
2.10
See raw data in appendix for
st
1
Hour
CO
Emissions
Emissions
Emissions
(g)
(g/hr)
4.79
84
14.53
116
Date: 21 July 2017
Page 7 of 15
CO
Heating
Efficiency
(g/min)
(% HHV)
1
67
2
70
Page 208 of 245