Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM
Test report #103124842MTL-001 (15 of 15)
Stove Builder International Inc.
Project No. G103124842
VI.B.(2).•
The tunnel velocity is calculated from a center point Pitot tube signal multiplied by an
adjustment factor. This factor is determined by a traverse of the tunnel as prescribed
in EPA Method 1. Final tunnel velocities and flow rates are calculated from EPA
Method 2, Equation 6.9 and 6.10. (Tunnel cross sectional area is the average from
both lines of traverse.)
Pitot tubes are cleaned before each test and leak checks are conducted after each
test.
VI.B.(3).•PM•SAMPLING•PROPORTIONALITY•
Proportionality was calculated in accordance with ASTM E2515-11. The data and
results are included in Appendix C.
VII.• CONCLUSION•
This test demonstrates that this unit is an affected facility under the definition given in the
regulation. The emission rate of 1.54 g/hr meets the EPA requirements for the Step 2
limits.
Model Series 2.3 – Escape 1800 therefore qualifies as mentioned above.
INTERTEK TESTING SERVICES NA
Evaluated by: _____________________
Reviewed by: ___________
Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy
TUNNEL•VELOCITY/FLOW•MEASUREMENT•
Claude Pelland, Eng.
Project Engineer – B&C
Brian Ziegler
Chief Engineer - Hearth
Date: 21 July 2017
Page 15 of 15
Page 216 of 245