Electricity Power Supply - Electrolux WB6-90 Installation Manual

Washer-extractors
Table of Contents

Advertisement

Table 4 (B2, C and correction factors for cable grouping)
Number of cables
The total current included for using Table 1 should be the maximum rated current for the machine divided by the
product of the different correction factors. Other correction factors may also be applied ; consult the cable
manufacturers.
Calculation : Example
• The machine has a rated current of 60 A.
• The ambient temperature is 45 °C ; Table 2 gives a correction factor of 0.91.
• Rubber cable insulant : Table 3 gives a correction factor of 0.92.
• The cable is fixed directly to the wall (Column C), with 2 cables side by side. Table 4 gives a correction factor of
0.85.
Taking Column C in Table 1 (wall fixing), we obtain a minimum cable section of : 3 x 25 mm².

20 Electricity power supply

Prior to use, the washer-extractor should be connected to a multi-pole switch prior to the machine to facilitate in-
stallation and service operations.
The electrical installation of the machine must be undertaken by qualified personnel.
Ensure that the electrical voltage is correct and that the power of your supply is sufficient, before connecting the
machine.
The main switch is located on the right side of the machine , identified by this sticker.
Note!
Installation manual
B2
Seated in Cable Duct
1
1.00
2
0.80
4
0.65
6
0.57
9
0.50
Total current :
_________________
E
Wall fixing or Cable trough
1.00
0.85
0.75
0.72
0.70
60 A
0.91 x 0.92 x 0.85
Caution
Caution
Caution
E
Cable tray
1.00
0.87
0.78
0.75
0.73
= 84 A
61