Figure 5-11 - Oil Separator - Gardner Denver AirSmart EAU99T Operating And Service Manual

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

If the leak develops through the packing, tighten the packing gland nut firmly with a wrench to reseat the
packing around the valve stem, then back off the nut until loose, and finally retighten the nut finger tight.
Tightening the packing nut too tight may cause erratic operation. An occasional drop of oil on the valve
stem at the packing nut will prolong packing life.
If valve malfunctions, check for bent or binding, paint or corrosion on valve stem, foreign material in valve,
erosion, or thermal system (capillary) failure. If foreign material or scale is likely, the use of a strainer in
the inlet water line is recommended.
WATER SHUTOFF VALVE - WATER-COOLED HEAT EXCHANGER (Optional Equipment) (
page
48)
- A magnetic solenoid-operated water shutoff valve rated at 150 psig (10.3 bar) water pressure
should be mounted in the water outlet line after the oil cooler. The valve should be wired into the
compressor control circuit so that the valve opens to allow water to flow any time the compressor is
running. When compressor stops under automatic control, or is shut off manually, the valve should close,
stopping water flow through the system. See Wiring Diagrams, pages 32 thru 35.
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
OIL RESERVOIR - The oil reservoir-separator combines multiple functions into one vessel. The lower
half is the oil reservoir, providing oil storage capacity for the system and the top portion, a primary oil
separation means. The reservoir also provides limited air storage for control and gauge actuation.
Figure 5-11 – OIL SEPARATOR
13-10-618
Page 61
,
Figure 5-3
211EAU797
(Ref. Drawing)