Gardner Denver AirSmart EAU99T Operating And Service Manual page 16

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

These compressors have aluminum oil coolers; do not use any cleaning
solution that is not compatible with aluminum. Use of improper solution may
result in damage to the cooler.
FOUNDATION - The Gardner Denver Rotary Screw compressor requires no special foundation, but
should be mounted on a smooth, solid surface. Whenever possible install the unit near level. Temporary
installation may be made at a maximum 10° angle lengthwise or 10° sidewise.
Mounting bolts are not normally required. However, installation conditions such as piping rigidity, angle of
tilt, or danger of shifting from outside vibration or moving vehicles may require the use of mounting bolts
and shims to provide uniform support for the base.
OIL RESERVOIR DRAIN - The oil drain is piped from the bottom of the reservoir to the side of the frame.
This drain is approximately 4.50 inches (115 mm) above the floor level. If this is not sufficient to
conveniently drain the oil some other methods of providing drain are:
1.
Elevate the compressor unit on a suitable structure to obtain the desired drain height.
If the compressor unit base is raised above floor level, the space between the
floor and the base bottom must be closed with solid material all around to
prevent recirculation of hot air from the oil cooler end and over temperature
operation.
2.
Construct an oil sump or trough below the floor level and pump or bail the drained oil.
3.
Pump oil from the reservoir filler opening or drain to a container.
ENCLOSURE - The compressor, electric motor, oil cooler and aftercooler are mounted inside the
enclosure. Service doors are provided for maintenance access. Be sure to allow enough space around
the unit for the doors to open completely.
Any of the enclosure doors may be removed by opening the door and lifting it up slightly to disengage the
hinges.
Ducting will be required on air-cooled quiet enclosure machines.
Do not operate the compressor with the fan and coupling guard removed.
Exposed fan and couplings may cause injury to personnel.
NOTICE
13-10-618
Page 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents