Gardner Denver AirSmart EAU99T Operating And Service Manual page 54

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
Excessive oil carry-over can damage equipment. Never fill oil reservoir above
the "FULL" marker.
LUBRICANT CHANGE PROCEDURE - Upgrading to a longer life lubricant is essentially a very
worthwhile practice. Following are the primary steps to be completed when upgrading or changing the
type of lubricant.
1.
Thoroughly drain system:
-
Drain oil from air end and cooler while hot.
-
Break low point connections and drain oil from pipe runs.
-
Dump oil from the filter and reinstall used filter.
2.
Fill the system with a 50 percent charge of the new lubricant:
-
Start the machine and stay there to observe.
-
Allow the machine to run about five minutes at temperature, or until temperature stabilizes, then
shut down.
3.
Thoroughly drain the machine.
4.
Change to a new filter and separator.
5.
Fill the system with a full charge of the new lubricant, then reinstall drain plug.
6.
Machine should then be run normally; however, total run time after the initial changeout should be 50
percent of normal anticipated service life of the new lubricant.
-
Drain all lubricant from the system, change the filter and separator, and replace with a full charge of
the new lubricant.
7.
Subsequent lubricant changeouts should be at normal intervals. (See "Oil Change Interval" Figure 5-
7, page 54.)
 
 
 
 
 
 
 
 
13-10-618
Page 53