STRUCTURE, FUNCTION AND MAINTENANCE STANDARD
1. Hydraulic filter
1A. Bypass valve
1B. Strainer
1C. Element
1D. Cooler check valve
2. Hydraulic tank
3. Suction strainer
4. Sight gauge
5. Oil filler cap
Specifications
Tank capacity: 500 l
Amount of oil inside tank: 380 l (at H level)
Safety valve
Relief cracking pressure: 16.7 ± 6.9 kPa
Suction cracking pressure: 0 – 0.49 kPa
Bypass valve set pressure: 0.15 ± 0.03 MPa
PC600, 600LC-7
{0.17 ± 0.07 kg/cm
}
2
{0 – 0.005 kg/cm
}
2
{1.5 ± 0.3 kg/cm
}
2
HYDRAULIC TANK, HYDRAULIC FILTER
10-33