STRUCTURE, FUNCTION AND MAINTENANCE STANDARD
1. Auto deceleration function
Function
•
If all the control levers are at neutral when wait-
ing for work or waiting for a dump truck, the en-
gine speed is automatically reduced to a
midrange speed to reduce fuel consumption and
noise.
•
If any lever is operated, the engine speed returns
immediately to the set speed.
10-146
MACHINE CONTROL SYSTEM
PC600, 600LC-7