Komatsu PC600LC-7 Manual page 181

Hide thumbs Also See for PC600LC-7:
Table of Contents

Advertisement

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD
1) Control method in each mode
A, E mode
Matching point in A, E mode: Rated output point
Model
Mode
A
E
When the load on the pump rises and the pres-
sure rises, the engine speed goes down.
At this time, the pump discharge is reduced and
the engine speed is set about the rated output
point. If the pressure lowers, the pump dis-
charge is increased until the engine speed is set
about the rated output point.
By repeating this control, the engine can always
be used at near the rated output point.
Compared with the A mode, which provides the
maximum output, the E mode lowers the engine
output to provide matching at a point which gives
better fuel consumption efficiency than the A
mode.
PC600, 600LC-7
PC600, PC600LC-7
287 kW/1,800 rpm
{385 HP/1,800 rpm}
247 kW/1,720 rpm
{331 HP/1,720 rpm}
MACHINE CONTROL SYSTEM
10-149