Midea AOUAMI AQS60X1o Installation & Owner's Manual page 83

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 49
ERROR
MALFUNCTION
CODE
OR PROTECTION
Module protection
DC generatrix low voltage
protection Heat pump syserm
high pressure protection
DC generatrix high voltage
protection Heat pump syserm
high pressure protection
MCE malfunction
Zero speed protection
Speed difference >15Hz
protection between
the front and the back clock
Speed difference >15Hz
protection between
the real and the setting speed
FAILURE CAUSE
AND CORRECTIVE ACTION
1. Check the Heat pump system pressure;
2. Check the phase resistance of compressor;
3. Check the U、V、W power line connection sequence
between the inventer board and the compressor;
4. Check the L1、L2、L3 power line connection between the
inventer board and the Filter board;
5. Check the inventer board.
79

Advertisement

Table of Contents
loading