Atal ATD-09 Instruction Manual

Digital thermo-hygro-barometer and datalogger

Advertisement

Quick Links

ATAL ATD-09
Digital thermo-hygro-barometer and datalogger
Instruction manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the ATD-09 and is the answer not in the manual?

Questions and answers

Summary of Contents for Atal ATD-09

  • Page 1 ATAL ATD-09 Digital thermo-hygro-barometer and datalogger Instruction manual...
  • Page 2 Manual for use of thermo-hygro-barometer ATAL ATD09 Instrument is designed for measurement of temperature, relative humidity, atmospheric pressure and pressure tendency. It enables to display the dew point temperature and atmospheric pressure corrected to the sea level. Measured values can be stored in programmable interval into internal non-volatile memory and transfer anytime to a PC.
  • Page 3 Operation conditions: Ambient temperature range: -10 to +60 °C Ambient relative humidity range: 5 to 95 %RH Outer characteristics in accordance with EN 33-2000-3: normal environment with characteristics AD1, AE1, AF1, AG1, AH1, AK1, AL1, AN1, AP1, AQ1, AR1, AS1, BA1, BE1 Not allowed manipulation: it is not allowed to touch sensors under the cover to avoid sensors damaging or to effect calibration.
  • Page 4 Displaying of actual measured values In this mode is instrument anytime after switching ON. It is possible to enter this mode from other modes by pressing or by repeating pressing of MENU key. Temperature in °C is displayed on the upper LCD line and relative humidity in %RH is displayed on the lower LCD line.
  • Page 5 Functions and settings available from menu Press MENU key to enter mode of viewing menu items one by one. Press arrow keys up and down to list all menu items. Press MENU key again to return to default mode (displaying of actual measured values).
  • Page 6 Each pressing of ENTER key causes displaying information on storing interval, actual logging mode (MODE), memory occupation (MEMO - in automatic logging mode memory occupation in % is displayed, in manual mode the number of logged values is displayed) and service information on software version (upper LCD line) together with instrument configuration on the LCD lower line.
  • Page 7 Logging mode In logging mode measured values are stored to instrument internal memory. Memory is non volatile, i.e. if battery voltage drops or battery is disconnected, stored data will not be lost. Instrument can work in two logging modes: automatic mode - actual measured values are stored to memory in adjustable time interval. Storing of the first value is synchronized with internal real time clock , so the memorizing is performed at sharp multiples of minutes, hours and days.
  • Page 8 Logging is started and instrument returns to default mode displaying actual values. Logging in progress is in default mode indicated with reading LOG on display. If memory is filled over 90 %, symbol LOG is blinking (only in automatic logging). Logging start with clearing memory and logging mode selection It is possible to clear memory only if logging is stopped.
  • Page 9 Logging is stopped after confirmation selection STOP YES by pressing ENTER key. Instrument then returns to default mode of displaying actual values. Connection of the instrument to a personal computer For connection of the instrument to a personal computer is designed the communication cable (included in delivery).
  • Page 10 During installation you will be invited to insert second diskette. In the end message of successful installation will occur. Quit the Installator by button Cancel. Now it is possible to run software from menu Start - Programs - ATAL - ATD. Software for Windows - instruction manual Communication with the instrument First connect communication cable to computer serial port.
  • Page 11 Buttons on tool bars (left to right) From disk opens file with measured values stored on disk From instrument reads measured values from instrument and store them to disk Table displays table of measured values Graph displays time graph of measured values Print prints table or graph to printer Exit...
  • Page 12 I.e. after modification of the correction constant all records existing in the instrument memory are recalculated with new constant by the PC program. ATAL instruments passed the following electromagnetic compatibility (EMC) tests: radiation: EN 55022 class B...