Tektronix P5934 Instruction Manual

Mass termination probe
Table of Contents

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

Table of Contents
loading

Summary of Contents for Tektronix P5934

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 P5934 Mass Termination Probe Instruction Manual www.tektronix.com *P077063600* 077-0636-00...
  • Page 3 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
  • Page 4 Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
  • Page 6: Table Of Contents

    Loading and equivalent circuits ................Specifications....................Maintenance......................Probe calibration information ................Probe service strategy information................Inspect or clean the probe..................Perform the functional check ................Repackage the probe ..................Replaceable Parts ....................Parts ordering information ................... Glossary Index P5934 Logic Analyzer Probe Instruction Manual...
  • Page 7 Table of Contents List of Figures Figure 1: P5934 Mass Termination Probe ............... Figure 2: P5934 probe labels..................Figure 3: Locating the probe-tip connector..............Figure 4: End view of the probe-tip connector..............Figure 5: Other indicators for pin 1 side .................
  • Page 8 Table 8: Pin 1 side probe channel assignments (nonstandard) ..........Table 9: Pin 38 side probe channel assignments (nonstandard) ..........Table 10: Lossy delay line values ................Table 11: Electrical and mechanical specifications ............Table 12: Environmental specifications................. Table 13: Service options..................P5934 Logic Analyzer Probe Instruction Manual...
  • Page 9: General Safety Summary

    Do not operate in wet/damp conditions. Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. Provide proper ventilation. Refer to the manual's installation instructions for details on installing the product so it has proper ventilation. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 10 DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product: P5934 Logic Analyzer Probe Instruction Manual...
  • Page 11: Environmental Considerations

    Restriction of hazardous This product is classified as an industrial monitoring and control instrument accessory, and is not required to comply with the substance restrictions of the substances recast RoHS Directive 2011/65/EU until July 22, 2017. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 12: Preface

    Preface Preface This document provides information on using the P5934 logic analyzer probe. Related documentation The following list and table provide information on the related documentation available for your Tektronix product. For additional information, refer to the Tektronix Web site (www.tektronix.com/manuals).
  • Page 13 Preface viii P5934 Logic Analyzer Probe Instruction Manual...
  • Page 14: Operating Basics

    SUT (system-under-test). Product description The P5934 probe connects 34 logic analyzer channels directly to the SUT or to a microprocessor probe adapter on the SUT. The probe acquires data from 32 input or output signals and two clocks, one clock and one qualifier, or two qualifier signals.
  • Page 15: Probe Accessory Information

    Operating basics Probe accessory information The P5934 probe includes accessories to connect the logic analyzer to the SUT. The following accessories are available: Latch housing assembly, edge-mount Latch housing assembly, vertical Mictor connector (surface mount, vertical receptacle) Mictor connector kit (Tektronix part number, 020-2228-xx; kit of 21 surface...
  • Page 16: Probe Label Overview

    Table 1: Color-coded label combinations (136- and 102-channel logic analyzers) Address Color on Pin 1 side Tan (CK:0, A3:7-0, A2:7-0) Color on Pin 38 side Orange (CK:1, A1:7-0, A0:7-0) P5934 Logic Analyzer Probe Instruction Manual...
  • Page 17: Apply The Labels To The Probe

    The adhesive on the vinyl labels is extremely strong. Carefully align each label to the intended outline on the probe connector and probe tip before attaching it to the probe. Once labels are placed on the probe, they become very difficult to remove. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 18: Figure 3: Locating The Probe-Tip Connector

    The position of the bent waves, the angled ends, are on the pin 1 side. Figure 4: End view of the probe-tip connector 4. Remove the pin 1 side label that you need from the sheet of labels. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 19: Figure 5: Other Indicators For Pin 1 Side

    6. Apply the associated pin 38 side label to the probe tip. (See Figure 6.) If necessary, see the color-coded combination tables on the previous pages for label information. Figure 6: Location of the pin 38 side label on the probe-tip P5934 Logic Analyzer Probe Instruction Manual...
  • Page 20: Figure 7: Applying Labels To The Probe Connectors

    To avoid mislabelling, hold the probe-tip in your hand and follow the cable to the probe connector. Match the color of the probe connector label to the probe-tip label. Figure 7: Applying labels to the probe connectors P5934 Logic Analyzer Probe Instruction Manual...
  • Page 21: Figure 8: Probe Label Placement Summary

    Operating basics The following figure summarizes the label placement for the probe. Figure 8: Probe label placement summary P5934 Logic Analyzer Probe Instruction Manual...
  • Page 22: Connect The Probe To The Logic Analyzer

    Connect to the SUT directly to a Mictor connector on the SUT. Connect to the SUT through a Mictor adapter. In the following procedures, a surface-mounted Mictor connector is shown in the illustrations. The procedures are the same for the edge-mounted connector. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 23: Connect The Probe Directly To The Sut

    2. Position the probe tip perpendicular to the connector, and gently connect the probe as shown in the following figure. (See Figure 10 on page 11.) 3. When connected, push the latch releases on the probe to set the latch. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 24: Figure 10: Connecting To A Surface- Or Edge-Mounted Connector

    Operating basics Figure 10: Connecting to a surface- or edge-mounted connector P5934 Logic Analyzer Probe Instruction Manual...
  • Page 25: Connect The Probes Using The Mictor Adapter

    This adapters require the use of the Compression-on-PCB to Mictor adapter land footprint. The following figure provides dimensional information; the dimensions are the same for both adapters. Figure 12: Dimensions of the Mictor adapters P5934 Logic Analyzer Probe Instruction Manual...
  • Page 26: Figure 13: Clearance For Probe Connection Using The Mictor Adapter

    Mictor adapter. (See Figure 13.) Note that the difference in clearance between the probe connection and the connection using the Mictor adapter is 3.68 mm (0.145-in.). Figure 13: Clearance for probe connection using the Mictor adapter P5934 Logic Analyzer Probe Instruction Manual...
  • Page 27: Disconnect The Probe From The Sut

    2. Continue to pull the probe tip straight out of the mating connector using the latch release grip. If you use an extender, grip the corners of the circuit board-end attached to the SUT, and gently pull it straight out of the connector. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 28: Reference

    Reference This section provides guidelines for designing a P5934 probe interface on the SUT. Mictor connectors and latch housings The probe contains 34 sets of signal connections (32 data channels and two clock or qualifier channels). The probe tip connection is a 38-pin Mictor connector. The following table lists Mictor connectors you can purchase that are compatible with the probe and compatible latch housings and connectors.
  • Page 29: Figure 15: Latch Housing Dimensions

    Reference Figure 15: Latch housing dimensions P5934 Logic Analyzer Probe Instruction Manual...
  • Page 30: P5934 Probe Dimensions

    Reference P5934 probe dimensions The following figure shows the dimensions of the P5934 probe, Figure 16: P5934 probe dimensions P5934 Logic Analyzer Probe Instruction Manual...
  • Page 31: Dimensions And Placement Of Mictor Connectors

    The following figure shows the dimensions and minimum placement of surface-mounted connectors on a SUT. The side-to-side dimension between connectors also applies to the edge-mounted connector. Figure 18: Dimensions and placement of a surface-mounted Mictor connector with latch housing P5934 Logic Analyzer Probe Instruction Manual...
  • Page 32: Mechanical Layout And Pin Numbering Sequence

    1 indicator on the Mictor connector. Even though the Mictor connector is keyed, you still need to know the location of pin 1 when connecting the probe. Figure 19: Surface-mounted connector layout (component side) P5934 Logic Analyzer Probe Instruction Manual...
  • Page 33: Figure 20: Edge-Mounted Connector Layout (Component Side)

    The edge-mounted connector does not have a keyhole. Be sure to position pin 1 correctly when building the SUT to maintain the correct mapping of signals from your SUT to the logic analyzer probe sections and channels. Figure 20: Edge-mounted connector layout (component side) P5934 Logic Analyzer Probe Instruction Manual...
  • Page 34: Standard Probe Channel Assignments

    Reference Standard probe channel assignments Tektronix recommends using the standard Probe channel assignments for your design. The 17 channels to which the probe connects on the logic analyzer cannot be changed. When mapping signals from your SUT to channels on the logic analyzer, keep the probe section, clock, and/or qualifier channels together as shown in the...
  • Page 35: Table 5: Pin 1 Side Probe Channel Assignments

    D1:6 E1:6 A1:5 C1:5 D1:5 E1:5 A1:4 D1:4 E1:4 C1:4 A1:3 C1:3 D1:3 E1:3 A1:2 C1:2 D1:2 E1:2 A1:1 C1:1 D1:1 E1:1 A1:0 C1:0 D1:0 E1:0 A0:7 C0:7 D0:7 E0:7 A0:6 C0:6 D0:6 E0:6 P5934 Logic Analyzer Probe Instruction Manual...
  • Page 36: Alternate Probe Channel Assignments

    The tables comply with the labeling schemes in the previous tables except for the 34-channel instrument on the Pin 38 side of the probe. The Mictor pin numbers are shown for reference only. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 37: Table 8: Pin 1 Side Probe Channel Assignments (Nonstandard)

    D1:3 E1:3 A1:2 C1:2 D1:2 E1:2 A1:1 C1:1 D1:1 E1:1 A1:0 C1:0 D1:0 E1:0 A0:7 D0:7 E0:7 C0:7 A0:6 D0:6 E0:6 C0:6 A0:5 C0:5 D0:5 E0:5 A0:4 C0:4 D0:4 E0:4 A0:3 C0:3 D0:3 E0:3 P5934 Logic Analyzer Probe Instruction Manual...
  • Page 38: Loading And Equivalent Circuits

    20 kΩ resistance returned to a 2.2 V supply. The following approximation of the probe loading is sufficient for most circuit simulation calculations. The following figure shows the equivalent circuit of the probe. Figure 21: Equivalent circuit for the probe P5934 Logic Analyzer Probe Instruction Manual...
  • Page 39: Specifications

    The following tables list the electrical, mechanical, and environmental specifications for the probe. These specifications are for a P5934 probe connected between a logic analyzer and a SUT. Refer to the TLA6400 Series Logic Analyzer Product Specifications & Performance Verification Technical Reference Manual (available on the TLA Documentation CD or downloadable from the Tektronix Web site) for a complete list of system specifications.
  • Page 40: Table 12: Environmental Specifications

    (86 °F) 5% to 45% relative humidity above 30 °C (86 °F) up to 71 °C (160 °F); non-condensing Altitude Operating up to 3000 m (9843 ft.) Non-operating up to 12,000 m (39370 ft.) P5934 Logic Analyzer Probe Instruction Manual...
  • Page 41 Reference P5934 Logic Analyzer Probe Instruction Manual...
  • Page 42: Maintenance

    Maintenance Probe calibration information The probe does not require calibration; however, the probe can be returned to Tektronix for functional verification. If a probe failure occurs, return the entire probe to Tektronix for repair. Probe service strategy information The following service options are available when you order your Tektronix...
  • Page 43: Perform The Functional Check

    If the original packaging is not available, use a corrugated cardboard shipping carton. 2. Add cushioning material to prevent the probes from moving inside the shipping container. 3. Enclose the following information when shipping the probe to a Tektronix Center: Owner’s address Name and phone number of a contact person...
  • Page 44: Replaceable Parts

    Replaceable Parts Parts ordering information Replacement parts are available through your local Tektronix field office or representative. Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements.
  • Page 45 Replaceable Parts P5934 Logic Analyzer Probe Instruction Manual...
  • Page 46: Glossary

    The end of the probe that connects to the SUT. It is also known as the probe head. System-Under-Test. Also known as the SUT. The logic analyzer connects to the SUT through the probe. P5934 Logic Analyzer Probe Instruction Manual...
  • Page 47 Glossary P5934 Logic Analyzer Probe Instruction Manual...
  • Page 48 30 vertical clearance, 18 related documentation, vii inspection and cleaning, 29 disconnecting repackage the probe, 30 probe calibration, 29 from the SUT, 14 replacement parts, 31 probe repackaging, 30 service strategy, 29 P5934 Logic Analyzer Probe Instruction Manual...
  • Page 49 Index surface-mounted connector dimensions, 18 Safety Summary, iv vertical clearance layout, 19 service options, 29 direct connection, 18 pin assignments, 21 specifications placement, 18 electrical, 26 environmental, 27 connecting probes, 10 mechanical, 26 P5934 Logic Analyzer Probe Instruction Manual...

Table of Contents