Man D 0836 LE 401 Operating Instructions Manual page 54

Table of Contents

Advertisement

Main fuses on terminal box
Three more main fuses are fitted in the
terminal box.
These fuses blow in the event of overcur-
rent or short circuit.
They separately protect
D the electronic fuel injection EDC,
F5=16 A
D the diagnosis system, F6=10 A
D and the external electrical connections,
F7=10 A
The fuses can be reset by the operator
using the keys fitted.
Charge control lamp on the terminal box
A charge control lamp is fitted on the ter-
minal box.
This should only light up at "Ignition on".
As soon as the engine is running, this
lamp should go out.
If it lights up when the engine is running,
there is a defect in the dynamo.
The battery is no longer being charged.
The monitoring system reports the fault
"Failure of charge voltage".
A restart can thus be a problem.
When the Emergency off button has been pressed it must be unlocked manually by turn-
ing.
Commissioning and operation
54
Top side of terminal box with the keys for
fuse F5 / F6 / F7
Emergency off
Top side of terminal box with charge con-
trol lamp

Hide quick links: