GS1 DataBar Omnidirectional/GS1 DataBar Truncated/GS1 DataBar Limited
❏ The first application identifier '01' is not included in the data.
❏ When printing the HRI characters, the first application identifier '01' is printed as '(01)' before
the packing identification code.
❏ A check digit need not to be attached to the barcode data.
❏ When printing the HRI character, a check digit is printed after a product code.
❏ For GS1 DataBar Limited, specify '0' or '1' for the first digit.
GS1 DataBar Expanded
❏ Specify the data of 2 to 255 digits.
❏ '()' is the delimiter for the application identifiers. (printed as the HRI character, but not
encoded.)
❏ Be sure to include all the application identifiers in the data.
❏ When the first data is '01' after deleting application identifiers, left and right parenthesis, and
'*' from the specified data, the 14th digit from the next of '01' is checked as a check digit. When
it is not correct, an error occurs.
❏ When the next data of '01' is fewer than 14 digits, a check digit is not checked. 
(The check digit is not automatically calculated, nor replaced with '*.' When '*' is specified, '*'
is ignored, and the rest of the data is shifted by 1 digit.)
❏ Specify the special character using the following format.
Control Character
Left parenthesis for the application identifier
Right parenthesis for the application identifier
Skipped character
76
FNC1
'*'
ASCII
HRI Character
{1
Space is printed.
(
'(' is printed.
)
')' is printed.
{*
Error
*
Not printed.