160 191
A0 BF
63% 75%
192 223
C0 DF
75% 87%
224 255
E0 FF
88% 100%
Control-channel - Dimmer intensity
Only available, if control channel Internal Programs is not active.
Decimal Hexad. Percentage S/F
0 255
00 FF
0% 100%
Control-channel – Speed
Only available, if control channel Internal Programs is active.
Decimal Hexad. Percentage S/F
0 255
0 FF
0% 100%
DMX-512 connection / connection between fixtures
The wires must not come into contact with each other, otherwise
Please note, the starting address depends upon which controller is being used.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
S Open
F Random strobe-effect with increasing speed
S Open
F Gradual adjustment of the dimmer intensity from 0 to 100 %
F Speed adjustment min to max
the fixtures will not work at all, or will not work properly.