Memory Transfer - Studiologic SL-2001 User Manual

Studiologic sl-2001: user manual
Hide thumbs Also See for SL-2001:
Table of Contents

Advertisement

The SL-2001 uses a dynamic memory allocation scheme, which means that the storage space for a preset is dependent on the
number of functions that are active in that preset. It is possible (but very unlikely) that the memory space will become full
before all presets have been programmed. The Memory Used screen displays the percentage of memory that has been pro-
grammed.
The number on the second line indicates the percentage of preset storage memory that has been used. If this number ever
approaches 99%, consider erasing some presets which are not needed to allow space for newer presets.
This screen may also be used to erase data from memory. Use control slider 4 to select the data to be erased. Select Cardio
erase the entire contents of a memory card currently inserted into the card slot (the switch on the card must be set for Enable).
Select All to erase all internal presets and global variables. Select PrstXXor CardXX to erase the current preset.
If the MEMORY-USED screen is entered while a Memory Card preset is active, the indicated percentage refers to the mem-
ory card space.

MEMORY TRANSFER

This utility function is used to transfer a complete set of 64 SL-2001 presets (plus all global-programmable settings) to or from
the memory card. It is also possible to save or load SL-2001 memory to/from a computer via a system-exclusive operation.
Before using the function, make sure that the card has been firmly inserted into the slot on the front panel.
Use Control Slider 1 to select either a Save or Load operation. If presets are to be saved to the card, the Write Protect switch
on the card must be set to Enable. The Alpha switch is used to start execution of the operation. When finished with the card
save operation, set the switch back to Protect.
For system exclusive transfers to a computer, first set the computer to record incoming data. The Alpha switch will start the
transmission of data. The sys-ex data will appear on all four MIDI outputs.
To load the SL-2001 memory via sys-ex, the Alpha switch must be pressed before the data is transmitted from the computer.
Any of the four MIDI inputs will accept the sys-ex data.