Can Function - Ebyte ECAN-E01S User Manual

Table of Contents

Advertisement

成都亿佰特电子科技有限公司

4.1.4. CAN function

Category
Category
Copyright©2012–2022,成都亿佰特电子科技有限公司
Name
Defaults
CAN baud rate
1000K
CAN working
mode
Normal
Subcontracting
time interval
1
(ms)
empty
Optional
empty
CANBuffer
Name
Defaults
Standard frame
7FF(HEX)
cap
Standard frame
000(HEX)
lower limit
Extended frame
cap
1FFFFFFF
Description
There are 10 options from 5K to 1000K. Users can also fill
in any baud rate value by themselves.
Normal: The CAN port can respond to the received CAN
frame normally;
Listen only: The CAN port works in the monitor mode and
does not respond;
The values that can be filled are: 1 to 39. When the CAN
The values that can be filled in are: 12 to 255. When the
CAN port does not receive a new data frame within the time
defined by the "packet time interval" (unit is ms), and the
number of sub-packet frames is not reached, the previous
All data frames received and not yet sent are encapsulated
into an Ethernet packet and sent to the network port.
This option is only valid in TCP working mode. It
determines whether to clear the data in the CAN port Buffer
after the connection is established. If not, the data in the
Buffer will be sent after the connection is established. If
clear when TCP connection is selected, the saved CAN
buffer will be cleared when the TCP connection is
established.
The upper limit and lower limit of the received
standard frame ID set by the user together determine
the standard frame ID range to be received.
The upper limit value and lower limit value of the
received extended frame ID set by the user together
determine the range of the extended frame ID to be
ECAN-E01S 用户使用说明
Description
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecan-e01

Table of Contents