Option
SEG13
Explanation
PAGE
Use of external control
Indication Details Indication
Indication
and Details
2
Option
SEG19
Individual control of a
Explanation
PAGE
remote controller
Indication Details Indication
0 or 1
Indication and
Details
3
* Advanced function: Controlling cooling/heating current or power saving with motion detect.
(*1) When Cooling or dry mode is off. The indoor fan operate in setting minutes.
(*2) Minimizing fan operation when thermostat is off
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
- Fan stops or operates Ultra low in Cooling when thermostat is off.
30
English
SEG14
SEG15
Setting the output of external
control / External heater signal /
Cooling operation signal /
Free Cooling control signal
Details
Indication
Details
External control
0
Disuse
0
(Thermo On)
External control
1
(Operation On)
ON/OFF
1
control
External heater
2
signal (*4)
External heater
3
signal (*4)
OFF
2
control
Cooling operation
4
signal (*5)
Free Cooling control
5
(Cooling Thermo On) (*6)
Window
3
ON/OFF
Free Cooling control
control
6
(Cooling/Dry Thermo
On) (*6)
SEG20
SEG21
Heating setting compensation / Removing condensate water
in heating mode
Details
Indication
Heating Setting
Compensation
0
Default
channel 1
1
3.6 °F (2°C)
2
9 °F (5°C)
2
channel 2
3
Default
3
channel 3
4
3.6 °F (2°C)
4
channel 4
5
9 °F (5°C)
SEG16
S-Plasma ion
Indication
Details
0
Disuse
1
Use
SEG22
Adjusted EEV step of
stopped unit during
oil return /defrost
mode.
Details
Indication Details Indication
Removing Condensate
Water in Heating Mode
Disuse
Disuse
Disuse
0
Default
Use (*7)
Use (*7)
Adjusted
1
EEV
positon
Use (*7)
SEG17
SEG18
Buzzer control
Hours of filter usage
Indication Details Indication
Details
Use
0
2
1000 Hour
buzzer
Disuse
1
6
2000 Hour
buzzer
SEG23
SEG24
Motion detect sensor
-
Details
0
Disuse
Turn out in 30min.
1
without motion
Turn out in 60min.
2
without motion
Turn out in 120min.
3
without motion
Turn out in 180min.
4
without motion
-
Turn out in 30min.
5
without motion or
*advanced function
Turn out in 60min.
6
without motion &
*advanced function
Turn out in 120min.
7
without motion &
*advanced function
Turn out in 180min.
8
without motion &
*advanced function

Advertisement