INSTALLATION

Typical Installation

INSTALLATION
Typical Installation
1
2
4
3
1 Water Supply
5 Union Coupling
2 Check Valve
6 Inline System
3 Optional Bypass
7 Flow
4 Ball Valve
8 Power

Environmental Requirements

Risk of malfunction can occur due to improper handling, installation, or
environment.
Handle with care to prevent damage to the plastic components.
Do not mount on equipment with excessive vibration.
Install in a location where temperature is within the range of product rating.
Do not install in corrosive environments.
Liquid-tight conduit and fittings must be used to maintain NEMA 4 rating.
Installation in direct sunlight can reduce system power and reduce drive life.
Decide on a location for the pump installation that is:
on a hard, level surface
suitable to the enclosure rating of the system
clean and well-ventilated
protected from freezing, flooding, and excessive heat
accessible for servicing
convenient for draining of the pump housing, tank, and service pipes
as close as possible to water source to minimize suction piping length
NOTE: When the pump is located at a distance from the water source, the piping may have to be
increased in diameter.
NOTE: The system is not designed to draw/lift water from a source below the pumping unit. There is
not an incoming flow requirement, other than that the system needs to be supplied with a constant
supply of water to keep the unit completely full of water at all times.