1. Push reset button
en
2.1 Press valve head
toward the outside in the
direction of the arrow until
valve head is disconnected
from gas can. Remove
valve head and gas can.
If you are still not able to remove gas can send tool to Hilti Repair Center.
Important: Gas can has to be declared as Hazard Material for shipment
3. Remove
remaining nails.
Disassemble
magazine from
tool
Clear all debris from the tool prior to reassembling.
22
Printed: 07.07.2013 | Doc-Nr: PUB / 5069869 / 000 / 00
If pushing reset button
does not solve the
problem go ahead with
step 2
4. Remove sleeve assy
X-100TN by first
pressing spring clip and
turning sleeve assy
The support leg can help to
press down the tool
perpentdicular to the base
material and thereby
improve the fastening
quality.
2. Remove gas can
from tool
5. Free piston with nail
punch X-100NP and
hammer
.
If this is possible go to
step 3
If this is not possible go to
step 2.1
6. Once piston is released,
push piston back by using
nail punch X-100NP. Clear
out any debris which may be
restricting the piston